Pressure 4 click

Pressure 4 click is an absolute barometric pressure measurement Click boardâ„¢, which features a low power consumption, high precision barometric pressure sensor.

click Product page


Click library

  • Author : MikroE Team
  • Date : Jan 2020.
  • Type : I2C/SPI type

Software Support

We provide a library for the Pressure4 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly form compilers IDE(recommended way), or downloaded from our LibStock, or found on mikroE github account.

Library Description

This library contains API for Pressure4 Click driver.

Standard key functions :

  • Config Object Initialization function.

    void pressure4_cfg_setup ( pressure4_cfg_t *cfg );

  • Initialization function.

    PRESSURE4_RETVAL pressure4_init ( pressure4_t *ctx, pressure4_cfg_t *cfg );

  • Click Default Configuration function.

    void pressure4_default_cfg ( pressure4_t *ctx );

Example key functions :

  • This function returns the contents of the chipid register.

    uint8_t pressure4_read_id ( pressure4_t *ctx );

  • This function returning the calulated temperature value.

    double pressure4_get_temperature ( pressure4_t *ctx );

  • This function returning the calulated value of the pressure.

    double pressure4_get_pressure ( pressure4_t *ctx );

Examples Description

This app measure barometric pressure.

The demo application is composed of two sections :

Application Init

Initializes the click board.

void application_init ( void )
{
log_cfg_t log_cfg;
LOG_MAP_USB_UART( log_cfg );
log_init( &logger, &log_cfg );
log_info( &logger, "---- Application Init ----\r\n" );
// Click initialization.
PRESSURE4_MAP_MIKROBUS( cfg, MIKROBUS_1 );
pressure4_init( &pressure4, &cfg );
pressure4_default_cfg( &pressure4 );
Delay_ms( 100 );
}

Application Task

The preassure and temperature data is read from the sensor and it is printed to the UART.

void application_task ( void )
{
double tmp;
tmp = pressure4_get_temperature( &pressure4 );
log_printf( &logger, "Temperature : %lf \r\n", tmp );
tmp = pressure4_get_pressure( &pressure4 );
log_printf( &logger, "Pressure : %lf hPa \r\n", tmp );
log_printf( &logger, "========================\r\n", tmp );
Delay_ms( 500 );
}

The full application code, and ready to use projects can be installed directly form compilers IDE(recommneded) or found on LibStock page or mikroE GitHub accaunt.

Other mikroE Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.Pressure4

Additional notes and informations

Depending on the development board you are using, you may need USB UART click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all Mikroelektronika compilers, or any other terminal application of your choice, can be used to read the message.


pressure4_get_pressure
double pressure4_get_pressure(pressure4_t *ctx)
Get pressure function.
application_task
void application_task(void)
Definition: main.c:61
pressure4_default_cfg
void pressure4_default_cfg(pressure4_t *ctx)
Click Default Configuration function.
PRESSURE4_MAP_MIKROBUS
#define PRESSURE4_MAP_MIKROBUS(cfg, mikrobus)
Definition: pressure4.h:54
pressure4_cfg_setup
void pressure4_cfg_setup(pressure4_cfg_t *cfg)
Config Object Initialization function.
application_init
void application_init(void)
Definition: main.c:33
pressure4_cfg_t
Click configuration structure definition.
Definition: pressure4.h:179
pressure4_get_temperature
double pressure4_get_temperature(pressure4_t *ctx)
Get temperature function.
pressure4_init
PRESSURE4_RETVAL pressure4_init(pressure4_t *ctx, pressure4_cfg_t *cfg)
Initialization function.