void ndirco2_cfg_setup (ndirco2_cfg_t *cfg)
 Config Object Initialization function. More...
 
NDIRCO2_RETVAL ndirco2_init (ndirco2_t *ctx, ndirco2_cfg_t *cfg)
 Initialization function. More...
 
void ndirco2_generic_write (ndirco2_t *ctx, uint8_t reg, uint8_t *data_buf, uint8_t len)
 Generic write function. More...
 
void ndirco2_generic_read (ndirco2_t *ctx, uint8_t reg, uint8_t *data_buf, uint8_t len)
 Generic read function. More...
 
uint8_t ndirco2_read_register (ndirco2_t *ctx, uint8_t register_address, uint16_t *data_out)
 Generic Read function. More...
 
uint8_t ndirco2_write_register (ndirco2_t *ctx, uint8_t register_address, uint8_t transfer_data)
 Generic Write function. More...
 
void ndirco2_read_current_address (ndirco2_t *ctx, uint8_t *data_out, uint8_t n_bytes)
 Current Address Read function. More...
 
void ndirco2_read_co2 (ndirco2_t *ctx, uint8_t set_check_mode, uint16_t *output_data)
 CO2 Concentration Read function. More...
 
uint8_t ndirco2_check_busy (ndirco2_t *ctx)
 Data Ready Check function. More...
 
uint8_t ndirco2_check_average_complete (ndirco2_t *ctx)
 Average Complete Check function. More...
 
void ndirco2_set_mode (ndirco2_t *ctx, uint8_t select_mode)
 Mode Set function. More...
 
void ndirco2_reset (ndirco2_t *ctx)
 Software Reset function. More...
 
uint8_t ndirco2_check_alarm (ndirco2_t *ctx)
 CO2 Concentration Limit Check function. More...
 

Detailed Description

Function Documentation

◆ ndirco2_cfg_setup()

void ndirco2_cfg_setup ( ndirco2_cfg_t cfg)

Config Object Initialization function.

Parameters
cfgClick configuration structure.

This function initializes click configuration structure to init state.

Note
All used pins will be set to unconnected state.

◆ ndirco2_check_alarm()

uint8_t ndirco2_check_alarm ( ndirco2_t ctx)

CO2 Concentration Limit Check function.

Parameters
ctxClick object.
Returns
0 - the CO2 concentration drops below ten times the value of Low Alarm Threshold register 1 - the CO2 concentration goes above ten times the value of High Alarm Threshold register

Function checks is CO2 concentration cross limit value, and when that happens then generates interrupt (ALARM pin).

◆ ndirco2_check_average_complete()

uint8_t ndirco2_check_average_complete ( ndirco2_t ctx)

Average Complete Check function.

Parameters
ctxClick object.
Returns
0 - averaging operation not completed yet, 1 - averaging operation completed

Function checks is number of measurements exceeded determined value (averaging operation is completed).

◆ ndirco2_check_busy()

uint8_t ndirco2_check_busy ( ndirco2_t ctx)

Data Ready Check function.

Parameters
ctxClick object.
Returns
0 - data readable, 1 - busy state

Function checks is data ready for reading by checking state of Busy pin.

◆ ndirco2_generic_read()

void ndirco2_generic_read ( ndirco2_t ctx,
uint8_t  reg,
uint8_t *  data_buf,
uint8_t  len 
)

Generic read function.

Parameters
ctxClick object.
regRegister address.
data_bufOutput data buf
lenNumber of the bytes to be read

This function reads data from the desired register.

◆ ndirco2_generic_write()

void ndirco2_generic_write ( ndirco2_t ctx,
uint8_t  reg,
uint8_t *  data_buf,
uint8_t  len 
)

Generic write function.

Parameters
ctxClick object.
regRegister address.
data_bufData buf to be written.
lenNumber of the bytes in data buf.

This function writes data to the desired register.

◆ ndirco2_init()

NDIRCO2_RETVAL ndirco2_init ( ndirco2_t ctx,
ndirco2_cfg_t cfg 
)

Initialization function.

Parameters
ctxClick object.
cfgClick configuration structure.

This function initializes all necessary pins and peripherals used for this click.

◆ ndirco2_read_co2()

void ndirco2_read_co2 ( ndirco2_t ctx,
uint8_t  set_check_mode,
uint16_t *  output_data 
)

CO2 Concentration Read function.

Parameters
ctxClick object.
set_check_mode0 - reads data after each measurement when data is ready to be read 1 - reads data after number of measurements determined by AVE register + 1
output_dataBuffer where 15-bit CO2 concentration data be stored

Function reads 15-bit CO2 concentration data from data registers only when data is ready for reading after each measurement or after number of measurements determined by AVE register + 1.

◆ ndirco2_read_current_address()

void ndirco2_read_current_address ( ndirco2_t ctx,
uint8_t *  data_out,
uint8_t  n_bytes 
)

Current Address Read function.

Parameters
ctxClick object.
data_outBuffer where data be stored
n_bytesNumber of bytes which be read

Function reads one byte data from the last accessed address + 1.

◆ ndirco2_read_register()

uint8_t ndirco2_read_register ( ndirco2_t ctx,
uint8_t  register_address,
uint16_t *  data_out 
)

Generic Read function.

Parameters
ctxClick object.
register_addressAddress which from data be read
data_outBuffer where data be stored
Returns
0 - OK, 1 - wrong address parameter

Function reads data from register.

◆ ndirco2_reset()

void ndirco2_reset ( ndirco2_t ctx)

Software Reset function.

Parameters
ctxClick object.

Function performs reset of device and after that puts device in power down mode when reset is done.

◆ ndirco2_set_mode()

void ndirco2_set_mode ( ndirco2_t ctx,
uint8_t  select_mode 
)

Mode Set function.

Parameters
ctxClick object.
select_mode0 - power down mode, 1 (value different from zero) - continuous operating mode

Function puts device in desired mode (power down or continuous operating mode).

◆ ndirco2_write_register()

uint8_t ndirco2_write_register ( ndirco2_t ctx,
uint8_t  register_address,
uint8_t  transfer_data 
)

Generic Write function.

Parameters
ctxClick object.
register_addressAddress where data be written
transfer_dataData which be written
Returns
0 - OK, 1 - wrong address parameter

Function writes one byte data to register.