microwave6  2.1.0.0
Main Page

Microwave 6 Click

Microwave 6 Click is a compact add-on board that utilizes the Doppler Shift Phenomenon to sense motion. This board features the PD-V8-S, a high-frequency microwave sensor from Ningbo Pdlux Electronic Technology. The transmitter on this transceiver works on a 5.8GHz frequency over the patch antenna, with a 2-3kHz pulse repetition frequency. The strength of the sensor’s output, in other words, the detection range, depends on the Signal-to-Noise ratio.

Click Product page


Click library

  • Author : Nenad Filipovic
  • Date : May 2023.
  • Type : ADC/I2C type

Software Support

We provide a library for the Microwave 6 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Library Description

This library contains API for Microwave 6 Click driver.

Standard key functions :

Example key functions :

Example Description

This example demonstrates the use of the Microwave 6 Click board™ by reading and displaying the results of AD conversion and motion detection.

The demo application is composed of two sections :

Application Init

The initialization of I2C or ADC module and log UART. After driver initialization, the app calculates the reference ADC value.

void application_init ( void )
{
log_cfg_t log_cfg;
microwave6_cfg_t microwave6_cfg;
LOG_MAP_USB_UART( log_cfg );
log_init( &logger, &log_cfg );
log_info( &logger, " Application Init " );
// Click initialization.
microwave6_cfg_setup( &microwave6_cfg );
MICROWAVE6_MAP_MIKROBUS( microwave6_cfg, MIKROBUS_1 );
err_t init_flag = microwave6_init( &microwave6, &microwave6_cfg );
if ( ( ADC_ERROR == init_flag ) || ( I2C_MASTER_ERROR == init_flag ) )
{
log_error( &logger, " Communication init." );
for ( ; ; );
}
log_printf( &logger, " Calibrating the sensor...\r\n" );
log_printf( &logger, " There must be no movement near the sensor!\r\n" );
log_printf( &logger, "----------------------------------\r\n" );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
if ( MICROWAVE6_OK == microwave6_read_voltage( &microwave6, &reference ) )
{
log_printf( &logger, " The sensor has been calibrated!\r\n" );
log_printf( &logger, " Detector AN Voltage : %.3f[V]\r\n", reference );
log_printf( &logger, "----------------------------------\r\n" );
Delay_ms ( 100 );
}
else
{
log_error( &logger, " Communication error." );
for ( ; ; );
}
log_printf( &logger, "The motion detector unit is ready.\r\n" );
log_printf( &logger, "----------------------------------\r\n" );
Delay_ms ( 100 );
}

Application Task

The demo application reads the ADC results, takes an ADC sample, compares the difference between the taken samples and the ADC reference value, and reports the movement if the difference is higher/lower than the selected threshold value. Results are being sent to the UART Terminal, where you can track their changes.

void application_task ( void )
{
if ( MICROWAVE6_OK == microwave6_read_voltage( &microwave6, &voltage ) )
{
if ( ( ( voltage + MICROWAVE6_THRESHOLD ) < reference ) ||
( ( voltage - MICROWAVE6_THRESHOLD ) > reference ) )
{
if ( MICROWAVE6_FLAG_SET == flag )
{
log_printf( &logger, " Motion detected!\r\n" );
log_printf( &logger, " Detector AN Voltage : %.3f[V]\r\n", voltage );
log_printf( &logger, "----------------------------------\r\n" );
Delay_ms ( 100 );
}
}
else
{
}
}
}

The full application code, and ready to use projects can be installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Other Mikroe Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.Microwave6

Additional notes and informations

Depending on the development board you are using, you may need USB UART Click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. UART terminal is available in all MikroElektronika compilers.


microwave6_t
Microwave 6 Click context object.
Definition: microwave6.h:125
MICROWAVE6_OK
@ MICROWAVE6_OK
Definition: microwave6.h:161
microwave6_cfg_t
Microwave 6 Click configuration object.
Definition: microwave6.h:140
MICROWAVE6_FLAG_SET
#define MICROWAVE6_FLAG_SET
Definition: main.c:31
MICROWAVE6_MAP_MIKROBUS
#define MICROWAVE6_MAP_MIKROBUS(cfg, mikrobus)
MikroBUS pin mapping.
Definition: microwave6.h:101
microwave6_read_voltage
err_t microwave6_read_voltage(microwave6_t *ctx, float *voltage)
Microwave 6 read voltage level function.
application_task
void application_task(void)
Definition: main.c:91
microwave6_cfg_setup
void microwave6_cfg_setup(microwave6_cfg_t *cfg)
Microwave 6 configuration object setup function.
microwave6_init
err_t microwave6_init(microwave6_t *ctx, microwave6_cfg_t *cfg)
Microwave 6 initialization function.
application_init
void application_init(void)
Definition: main.c:38
MICROWAVE6_THRESHOLD
#define MICROWAVE6_THRESHOLD
Definition: main.c:29
microwave6_read_raw_adc
err_t microwave6_read_raw_adc(microwave6_t *ctx, uint16_t *raw_adc)
Microwave 6 read raw ADC value function.
microwave6_set_vref
err_t microwave6_set_vref(microwave6_t *ctx, float vref)
Microwave 6 set vref function.
MICROWAVE6_FLAG_CLEAR
#define MICROWAVE6_FLAG_CLEAR
Definition: main.c:30