pwrmeter390a  2.1.0.0
Macros
PWR Meter 3 90A Registers List

List of registers of PWR Meter 3 90A Click driver. More...

Macros

#define PWRMETER390A_REG_EEPROM_0B   0x0B
 PWR Meter 3 90A EEPROM registers. More...
 
#define PWRMETER390A_REG_EEPROM_0C   0x0C
 
#define PWRMETER390A_REG_EEPROM_0D   0x0D
 
#define PWRMETER390A_REG_EEPROM_0E   0x0E
 
#define PWRMETER390A_REG_EEPROM_0F   0x0F
 
#define PWRMETER390A_REG_SHADOW_1B   0x1B
 PWR Meter 3 90A SHADOW registers. More...
 
#define PWRMETER390A_REG_SHADOW_1C   0x1C
 
#define PWRMETER390A_REG_SHADOW_1D   0x1D
 
#define PWRMETER390A_REG_SHADOW_1E   0x1E
 
#define PWRMETER390A_REG_SHADOW_1F   0x1F
 
#define PWRMETER390A_REG_VOLATILE_20   0x20
 PWR Meter 3 90A VOLATILE registers. More...
 
#define PWRMETER390A_REG_VOLATILE_21   0x21
 
#define PWRMETER390A_REG_VOLATILE_22   0x22
 
#define PWRMETER390A_REG_VOLATILE_25   0x25
 
#define PWRMETER390A_REG_VOLATILE_26   0x26
 
#define PWRMETER390A_REG_VOLATILE_27   0x27
 
#define PWRMETER390A_REG_VOLATILE_28   0x28
 
#define PWRMETER390A_REG_VOLATILE_29   0x29
 
#define PWRMETER390A_REG_VOLATILE_2A   0x2A
 
#define PWRMETER390A_REG_VOLATILE_2C   0x2C
 
#define PWRMETER390A_REG_VOLATILE_2D   0x2D
 
#define PWRMETER390A_REG_VOLATILE_2F   0x2F
 
#define PWRMETER390A_REG_VOLATILE_30   0x30
 

Detailed Description

List of registers of PWR Meter 3 90A Click driver.

Macro Definition Documentation

◆ PWRMETER390A_REG_EEPROM_0B

#define PWRMETER390A_REG_EEPROM_0B   0x0B

PWR Meter 3 90A EEPROM registers.

Specified register for EEPROM of PWR Meter 3 90A Click driver.

◆ PWRMETER390A_REG_EEPROM_0C

#define PWRMETER390A_REG_EEPROM_0C   0x0C

◆ PWRMETER390A_REG_EEPROM_0D

#define PWRMETER390A_REG_EEPROM_0D   0x0D

◆ PWRMETER390A_REG_EEPROM_0E

#define PWRMETER390A_REG_EEPROM_0E   0x0E

◆ PWRMETER390A_REG_EEPROM_0F

#define PWRMETER390A_REG_EEPROM_0F   0x0F

◆ PWRMETER390A_REG_SHADOW_1B

#define PWRMETER390A_REG_SHADOW_1B   0x1B

PWR Meter 3 90A SHADOW registers.

Specified register for SHADOW of PWR Meter 3 90A Click driver.

Note
At power up, all shadow registers are loaded from EEPROM, including all configuration parameters. The shadow registers can be written to in order to change the device behavior without having to perform an EEPROM write. Any changes made in shadow memory are volatile and do not persist through a reset event.

◆ PWRMETER390A_REG_SHADOW_1C

#define PWRMETER390A_REG_SHADOW_1C   0x1C

◆ PWRMETER390A_REG_SHADOW_1D

#define PWRMETER390A_REG_SHADOW_1D   0x1D

◆ PWRMETER390A_REG_SHADOW_1E

#define PWRMETER390A_REG_SHADOW_1E   0x1E

◆ PWRMETER390A_REG_SHADOW_1F

#define PWRMETER390A_REG_SHADOW_1F   0x1F

◆ PWRMETER390A_REG_VOLATILE_20

#define PWRMETER390A_REG_VOLATILE_20   0x20

PWR Meter 3 90A VOLATILE registers.

Specified register for VOLATILE of PWR Meter 3 90A Click driver.

◆ PWRMETER390A_REG_VOLATILE_21

#define PWRMETER390A_REG_VOLATILE_21   0x21

◆ PWRMETER390A_REG_VOLATILE_22

#define PWRMETER390A_REG_VOLATILE_22   0x22

◆ PWRMETER390A_REG_VOLATILE_25

#define PWRMETER390A_REG_VOLATILE_25   0x25

◆ PWRMETER390A_REG_VOLATILE_26

#define PWRMETER390A_REG_VOLATILE_26   0x26

◆ PWRMETER390A_REG_VOLATILE_27

#define PWRMETER390A_REG_VOLATILE_27   0x27

◆ PWRMETER390A_REG_VOLATILE_28

#define PWRMETER390A_REG_VOLATILE_28   0x28

◆ PWRMETER390A_REG_VOLATILE_29

#define PWRMETER390A_REG_VOLATILE_29   0x29

◆ PWRMETER390A_REG_VOLATILE_2A

#define PWRMETER390A_REG_VOLATILE_2A   0x2A

◆ PWRMETER390A_REG_VOLATILE_2C

#define PWRMETER390A_REG_VOLATILE_2C   0x2C

◆ PWRMETER390A_REG_VOLATILE_2D

#define PWRMETER390A_REG_VOLATILE_2D   0x2D

◆ PWRMETER390A_REG_VOLATILE_2F

#define PWRMETER390A_REG_VOLATILE_2F   0x2F

◆ PWRMETER390A_REG_VOLATILE_30

#define PWRMETER390A_REG_VOLATILE_30   0x30