TOP Contributors

  1. MIKROE (2663 codes)
  2. Alcides Ramos (358 codes)
  3. Shawon Shahryiar (307 codes)
  4. jm_palomino (112 codes)
  5. Chisanga Mumba (90 codes)
  6. S P (73 codes)
  7. dany (71 codes)
  8. MikroBUS.NET Team (35 codes)
  9. NART SCHINACKOW (34 codes)
  10. Armstrong Subero (27 codes)

Most Downloaded

  1. Timer Calculator (137094 times)
  2. FAT32 Library (70236 times)
  3. Network Ethernet Library (56122 times)
  4. USB Device Library (46434 times)
  5. Network WiFi Library (42071 times)
  6. FT800 Library (41384 times)
  7. GSM click (29112 times)
  8. mikroSDK (26561 times)
  9. PID Library (26489 times)
  10. microSD click (25486 times)
Libstock prefers package manager

Package Manager

We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]

< Back
mikroSDK Library

TempHum 6 click

Rating:

0

Author: MIKROE

Last Updated: 2024-04-03

Package Version: 2.1.0.16

mikroSDK Library: 2.0.0.0

Category: Temperature & humidity

Downloaded: 188 times

Not followed.

License: MIT license  

Temp&Hum 6 click is a smart temperature and humidity sensing click board™, packed with features that allow easy and simple integration into any design.

No Abuse Reported

Do you want to subscribe in order to receive notifications regarding "TempHum 6 click" changes.

Do you want to unsubscribe in order to stop receiving notifications regarding "TempHum 6 click" changes.

Do you want to report abuse regarding "TempHum 6 click".

  • mikroSDK Library 1.0.0.0
  • Comments (0)

mikroSDK Library Blog


Temp Hum 6 click

Temp&Hum 6 click is a smart temperature and humidity sensing click board™, packed with features that allow easy and simple integration into any design.

temphum6_click.png

click Product page


Click library

  • Author : MikroE Team
  • Date : dec 2019.
  • Type : I2C type

Software Support

We provide a library for the TempHum6 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly form compilers IDE(recommended way), or downloaded from our LibStock, or found on mikroE github account.

Library Description

This library contains API for TempHum6 Click driver.

Standard key functions :

  • Config Object Initialization function.

    void temphum6_cfg_setup ( temphum6_cfg_t *cfg );

  • Initialization function.

    TEMPHUM6_RETVAL temphum6_init ( temphum6_t ctx, temphum6_cfg_t cfg );

  • Click Default Configuration function.

    void temphum6_default_cfg ( temphum6_t *ctx );

Example key functions :

  • This function returns read Temperature data.

    float temphum6_read_temperature ( temphum6_t *ctx, uint8_t temp_in );

  • This function returns read relative Humidity data.

    float temphum6_read_relative_huminidy( temphum6_t *ctx );

  • This function returns the device part id.

    uint16_t temphum6_get_part_id ( temphum6_t *ctx );

Examples Description

This application emasures temperature and humidity.

The demo application is composed of two sections :

Application Init

Initialization driver init and reset device and read Part ID


void application_init ( void )
{
    log_cfg_t log_cfg;
    temphum6_cfg_t cfg;
    uint16_t part_id;

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_info( &logger, "---- Application Init ----" );

    //  Click initialization.

    temphum6_cfg_setup( &cfg );
    TEMPHUM6_MAP_MIKROBUS( cfg, MIKROBUS_1 );
    temphum6_init( &temphum6, &cfg );

    temphum6_reset( &temphum6 );

    part_id = temphum6_get_part_id( &temphum6 );
    if ( part_id == TEMPHUM6_PART_ID )
    {
        log_printf( &logger, "Device OK - read ID is OK" );
    }
    else
    {
        log_printf( &logger, "Device ERROR - read ID is NOT OK" );
    }
}

Application Task

Reads Temperature and Huminidy data and logs this data to USBUART every 1sec.


void application_task ( void )
{
    //  Task implementation.

    float temp;
    float hum;

    temp = temphum6_read_temperature( &temphum6, TEMPHUM6_TEMP_IN_CELSIUS );
    log_printf( &logger, "Temperature is %f C\r\n");

    hum = temphum6_read_relative_huminidy( &temphum6 );
    log_printf( &logger, "Huminidy is %f %%RH\r\n");

    log_printf( &logger, "------------------\r\n");
    Delay_ms ( 1000 );
}

The full application code, and ready to use projects can be installed directly form compilers IDE(recommneded) or found on LibStock page or mikroE GitHub accaunt.

Other mikroE Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.TempHum6

Additional notes and informations

Depending on the development board you are using, you may need USB UART click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all Mikroelektronika compilers, or any other terminal application of your choice, can be used to read the message.


ALSO FROM THIS AUTHOR

EERAM 2 click

0

EERAM 2 Click is a standalone serial SRAM memory that includes shadow non-volatile backup. EERAM uses a small external capacitor to provide the energy needed to move the contents of the SRAM to the non-volatile cells when system power is lost.

[Learn More]

LTE IoT 2 click

5

LTE IoT 2 click is a Click board that allows connection to the LTE networks, featuring Quectel BG96 LTE module, which offers two LTE technologies aimed at Machine to Machine communication (M2M) and Internet of Things (IoT).

[Learn More]

Buck 13 click

5

Buck 13 Click is a high-efficiency step-down converter which provides a highly regulated output voltage derived from the connected power source, rated from 4.5V to 5.5V.

[Learn More]