TOP Contributors

  1. MIKROE (2784 codes)
  2. Alcides Ramos (405 codes)
  3. Shawon Shahryiar (307 codes)
  4. jm_palomino (133 codes)
  5. Bugz Bensce (97 codes)
  6. S P (73 codes)
  7. dany (71 codes)
  8. MikroBUS.NET Team (35 codes)
  9. NART SCHINACKOW (34 codes)
  10. Armstrong Subero (27 codes)

Most Downloaded

  1. Timer Calculator (141291 times)
  2. FAT32 Library (74089 times)
  3. Network Ethernet Library (58715 times)
  4. USB Device Library (48826 times)
  5. Network WiFi Library (44525 times)
  6. FT800 Library (44073 times)
  7. GSM click (30805 times)
  8. mikroSDK (29658 times)
  9. PID Library (27355 times)
  10. microSD click (27251 times)
Libstock prefers package manager

Package Manager

We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]

< Back
mikroSDK Library

TempHum 7 Click

Rating:

0

Author: MIKROE

Last Updated: 2024-10-31

Package Version: 2.1.0.16

mikroSDK Library: 2.0.0.0

Category: Temperature & humidity

Downloaded: 282 times

Not followed.

License: MIT license  

Temp&Hum 7 Click is a Click board™ which is perfectly suited for measuring the relative humidity (RH) and temperature.

No Abuse Reported

Do you want to subscribe in order to receive notifications regarding "TempHum 7 Click" changes.

Do you want to unsubscribe in order to stop receiving notifications regarding "TempHum 7 Click" changes.

Do you want to report abuse regarding "TempHum 7 Click".

  • mikroSDK Library 1.0.0.0
  • Comments (0)

mikroSDK Library Blog


Temp&Hum 7 Click

Temp&Hum 7 Click is a Click board™ which is perfectly suited for measuring the relative humidity (RH) and temperature.

temphum7_click.png

Click Product page


Click library

  • Author : MikroE Team
  • Date : Nov 2019.
  • Type : I2C type

Software Support

We provide a library for the TempHum7 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly form compilers IDE(recommended way), or downloaded from our LibStock, or found on mikroE github account.

Library Description

This library contains API for TempHum7 Click driver.

Standard key functions :

  • Config Object Initialization function.

    void temphum7_cfg_setup ( temphum7_cfg_t *cfg );

  • Initialization function.

    TEMPHUM7_RETVAL temphum7_init ( temphum7_t ctx, temphum7_cfg_t cfg );

  • Click Default Configuration function.

    void temphum7_default_cfg ( temphum7_t *ctx );

Example key functions :

  • Relative humidity.

    float temphum7_get_relative_humidity ( temphum7_t *ctx, uint8_t mode_data );

  • Get temerature.

    float temphum7_get_temperature ( temphum7_t *ctx, uint8_t mode_data );

  • Firmware revision.

    uint8_t temphum7_get_firmware_revision ( temphum7_t *ctx );

Examples Description

This application measurement temperature and humidity data.

The demo application is composed of two sections :

Application Init

Initializes device and logger module and sets default configuration for measurements.

void application_init ( void )
{
    log_cfg_t log_cfg;
    temphum7_cfg_t cfg;

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init ( &logger, &log_cfg );
    log_info ( &logger, "---- Application Init ----" );

    //  Click initialization.

    temphum7_cfg_setup ( &cfg );
    TEMPHUM7_MAP_MIKROBUS ( cfg, MIKROBUS_1 );
    temphum7_init ( &temphum7, &cfg );

    temphum7_default_cfg( &temphum7 );
} 

Application Task

Calculates and Logs temperature and relative humidity

void application_task ( void )
{

    temperature = temphum7_get_temperature ( &temphum7, TEMPHUM7_HOLD_MASTER_MODE );
    mikrobus_printf ( "-> Temperature: %f C/r/n", temperature );

    relative_humidity = temphum7_get_relative_humidity ( &temphum7, TEMPHUM7_HOLD_MASTER_MODE );
    mikrobus_printf ( "-> Relative humidity: %f %%RH/r/n ", relative_humidity );

    Delay_ms ( 1000 );
}

The full application code, and ready to use projects can be installed directly form compilers IDE(recommneded) or found on LibStock page or mikroE GitHub accaunt.

Other mikroE Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.TempHum7

Additional notes and informations

Depending on the development board you are using, you may need USB UART Click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all Mikroelektronika compilers, or any other terminal application of your choice, can be used to read the message.


ALSO FROM THIS AUTHOR

Tilt click

5

Tilt click carries RPI-1035, a 4-directional optical tilt sensor. This type of sensor provides positional feedback for left, right, up or down movements. Tilt click communicates with the target board microcontroller through mikroBUS PWM and INT lines, used here for vout1 and vout2 outputs from the sensor.

[Learn More]

Thermo 4 Click

0

THERMO 4 Click carries the LM75A digital temperature sensor and thermal watchdog. The sensor has the range from −55 °C to +125 °C.

[Learn More]

ccRF 2 Click

0

ccRF2 Click carries CC1120, the fully integrated, high-performance single-chip radio transceiver with extremely low power consumption.

[Learn More]