TOP Contributors

  1. MIKROE (2654 codes)
  2. Alcides Ramos (352 codes)
  3. Shawon Shahryiar (307 codes)
  4. jm_palomino (112 codes)
  5. Chisanga Mumba (90 codes)
  6. S P (73 codes)
  7. dany (71 codes)
  8. MikroBUS.NET Team (35 codes)
  9. NART SCHINACKOW (34 codes)
  10. Armstrong Subero (27 codes)

Most Downloaded

  1. Timer Calculator (136746 times)
  2. FAT32 Library (69953 times)
  3. Network Ethernet Library (55942 times)
  4. USB Device Library (46267 times)
  5. Network WiFi Library (41887 times)
  6. FT800 Library (41173 times)
  7. GSM click (28985 times)
  8. PID Library (26414 times)
  9. mikroSDK (26363 times)
  10. microSD click (25377 times)
Libstock prefers package manager

Package Manager

We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]

< Back
mikroSDK Library

TempHum 16 click

Rating:

0

Author: MIKROE

Last Updated: 2024-04-03

Package Version: 2.1.0.13

mikroSDK Library: 2.0.0.0

Category: Temperature & humidity

Downloaded: 139 times

Not followed.

License: MIT license  

Temp&Hum 16 Click is a compact add-on board that represents temperature and humidity sensing solutions. This board features the WSEN-HIDS (252.0.0.50001), a MEMS-based capacitive humidity sensor with an integrated ASIC and I2C and SPI serial communication from Würth Elektronik. A silicon-based temperature sensor is also integrated within the same package. ASIC contains the multiplier, operational amplifier, analog-to-digital converter, and other signal conditioning blocks like controller logics and interrupts. It converts the analog signal from humidity and temperature sensing elements into 16-bit digital humidity and temperature values. The 252.0.0.50001 is factory calibrated for both humidity and temperature measurements with no further calibration required. This Click board™ is an ideal solution to be used in various temperature and humidity-related applications.

No Abuse Reported

Do you want to subscribe in order to receive notifications regarding "TempHum 16 click" changes.

Do you want to unsubscribe in order to stop receiving notifications regarding "TempHum 16 click" changes.

Do you want to report abuse regarding "TempHum 16 click".

  • Information
  • Comments (0)

mikroSDK Library Blog


Temp&Hum 16 click

Temp&Hum 16 Click is a compact add-on board that represents temperature and humidity sensing solutions. This board features the WSEN-HIDS (2525020210001), a MEMS-based capacitive humidity sensor with an integrated ASIC and I2C and SPI serial communication from Würth Elektronik. A silicon-based temperature sensor is also integrated within the same package. ASIC contains the multiplier, operational amplifier, analog-to-digital converter, and other signal conditioning blocks like controller logics and interrupts. It converts the analog signal from humidity and temperature sensing elements into 16-bit digital humidity and temperature values. The 2525020210001 is factory calibrated for both humidity and temperature measurements with no further calibration required. This Click board™ is an ideal solution to be used in various temperature and humidity-related applications.

temphum16_click.png

click Product page


Click library

  • Author : Nenad Filipovic
  • Date : May 2021.
  • Type : I2C/SPI type

Software Support

We provide a library for the TempHum16 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Library Description

This library contains API for TempHum16 Click driver.

Standard key functions :

  • temphum16_cfg_setup Config Object Initialization function.

    void temphum16_cfg_setup ( temphum16_cfg_t *cfg );
  • temphum16_init Initialization function.

    TEMPHUM16_RETVAL temphum16_init ( temphum16_t *ctx, temphum16_cfg_t *cfg );
  • temphum16_default_cfg Click Default Configuration function.

    void temphum16_default_cfg ( temphum16_t *ctx );

Example key functions :

  • temphum16_check_ready Temp&Hum 16 check ready function.

    uint8_t temphum16_check_ready ( temphum16_t *ctx );
  • temphum16_get_humidity Temp&Hum 16 get humidity function.

    err_t temphum16_get_humidity ( temphum16_t *ctx, float *humidity );
  • temphum16_get_temperature Temp&Hum 16 get temperature function.

    err_t temphum16_get_temperature ( temphum16_t *ctx, float *temperature );

Example Description

This library contains API for the Temp&Hum 16 Click driver. This demo application shows an example of humidity and temperature measurement.

The demo application is composed of two sections :

Application Init

Initialization of SPI or I2C module and log UART. After driver initialization and default settings, the app display retrieves the sensor parameters such as temperature and humidity.


void application_init ( void ) {
    log_cfg_t log_cfg;              /**< Logger config object. */
    temphum16_cfg_t temphum16_cfg;  /**< Click config object. */

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_info( &logger, " Application Init " );

    // Click initialization.

    temphum16_cfg_setup( &temphum16_cfg );
    TEMPHUM16_MAP_MIKROBUS( temphum16_cfg, MIKROBUS_1 );
    err_t init_flag  = temphum16_init( &temphum16, &temphum16_cfg );
    if ( ( init_flag == I2C_MASTER_ERROR ) || ( init_flag == SPI_MASTER_ERROR ) ) {
        log_info( &logger, " Application Init Error. " );
        log_info( &logger, " Please, run program again... " );

        for ( ; ; );
    }

    temphum16_default_cfg ( &temphum16 );
    log_info( &logger, " Application Task " );
    Delay_ms ( 100 );

    temphum16_get_device_id( &temphum16, &device_id );
    log_printf( &logger, "-----------------------\r\n" );
    log_printf( &logger, "  Check communication  \r\n" ); 
    if ( device_id == TEMPHUM16_DEVICE_ID ){
        log_printf( &logger, "      Successful   \r\n" );    
    } else {
        log_printf( &logger, "        Failed     \r\n" );

        for ( ; ; );
    }

    log_printf( &logger, "-----------------------\r\n" );
    log_printf( &logger, "   Start measurements  \r\n" );
    log_printf( &logger, "-----------------------\r\n" );
}

Application Task

This is an example that shows the use of a Temp&Hum 16 Click board™. Logs humidity [ % ] and temperature [ degree Celsius ] data. Results are being sent to the Usart Terminal where you can track their changes.


void application_task ( void ) {
    if ( temphum16_check_ready( &temphum16 ) == TEMPHUM16_DRDY ) {
        temphum16_get_temperature( &temphum16, &temperature );
        log_printf( &logger, " Temperature : %.2f C\r\n", temperature ); 

        temphum16_get_humidity( &temphum16, &humidity );
        log_printf( &logger, " Humidity    : %.2f %%\r\n", humidity ); 
        log_printf( &logger, "-----------------------\r\n" );
        Delay_ms ( 1000 );
    }
}

The full application code, and ready to use projects can be installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Other Mikroe Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.TempHum16

Additional notes and informations

Depending on the development board you are using, you may need USB UART click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. UART terminal is available in all MikroElektronika compilers.


ALSO FROM THIS AUTHOR

HW Monitor click

0

HW Monitor Click is a compact add-on board used to monitor and regulate the performance of various hardware components within an embedded system. This board features the LM96080, an I2C-configurable system hardware monitor from Texas Instruments that contains a 10-bit delta-sigma ADC capable of measuring seven positive voltages and local temperature. The LM96080 also has two programmable fan speed monitoring inputs besides other hardware monitoring functions like chassis intrusion detection, additional external interrupt input, master reset for external purposes, as well as a sequencer that performs watchdog window comparisons of all measured values.

[Learn More]

Hall Current 13 click

0

Hall Current 13 Click is a compact add-on board that provides economical and precise AC or DC current sensing solutions. This board features the TMCS1107-Q1, a galvanically isolated Hall-effect current sensor capable of DC or AC current measurement with high accuracy, excellent linearity, and temperature stability from Texas Instruments. It enables the lowest drift, <3% full-scale error, and highest accuracy over time and temperature. It also provides a reliable 420V lifetime working voltage and 3kVRMS isolation between the current path and circuitry with uni/bidirectional current sensing. Besides, the user is allowed to process the output signal in analog or digital form.

[Learn More]

DeviceDrive click

5

DeviceDrive Click is a complete Cloud-on-Module solution with Wi-Fi functionality and integrated PCB antenna.

[Learn More]