TOP Contributors

  1. MIKROE (2784 codes)
  2. Alcides Ramos (405 codes)
  3. Shawon Shahryiar (307 codes)
  4. jm_palomino (133 codes)
  5. Bugz Bensce (97 codes)
  6. S P (73 codes)
  7. dany (71 codes)
  8. MikroBUS.NET Team (35 codes)
  9. NART SCHINACKOW (34 codes)
  10. Armstrong Subero (27 codes)

Most Downloaded

  1. Timer Calculator (141683 times)
  2. FAT32 Library (74746 times)
  3. Network Ethernet Library (59203 times)
  4. USB Device Library (49221 times)
  5. Network WiFi Library (44990 times)
  6. FT800 Library (44518 times)
  7. GSM click (31195 times)
  8. mikroSDK (30094 times)
  9. microSD click (27578 times)
  10. PID Library (27537 times)
Libstock prefers package manager

Package Manager

We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]

< Back
mikroSDK Library

TempHum 16 Click

Rating:

0

Author: MIKROE

Last Updated: 2024-10-31

Package Version: 2.1.0.15

mikroSDK Library: 2.0.0.0

Category: Temperature & humidity

Downloaded: 459 times

Not followed.

License: MIT license  

Temp&Hum 16 Click is a compact add-on board that represents temperature and humidity sensing solutions. This board features the WSEN-HIDS (252.0.0.50001), a MEMS-based capacitive humidity sensor with an integrated ASIC and I2C and SPI serial communication from Würth Elektronik. A silicon-based temperature sensor is also integrated within the same package. ASIC contains the multiplier, operational amplifier, analog-to-digital converter, and other signal conditioning blocks like controller logics and interrupts. It converts the analog signal from humidity and temperature sensing elements into 16-bit digital humidity and temperature values. The 252.0.0.50001 is factory calibrated for both humidity and temperature measurements with no further calibration required. This Click board™ is an ideal solution to be used in various temperature and humidity-related applications.

No Abuse Reported

Do you want to subscribe in order to receive notifications regarding "TempHum 16 Click" changes.

Do you want to unsubscribe in order to stop receiving notifications regarding "TempHum 16 Click" changes.

Do you want to report abuse regarding "TempHum 16 Click".

  • Information
  • Comments (0)

mikroSDK Library Blog


Temp&Hum 16 Click

Temp&Hum 16 Click is a compact add-on board that represents temperature and humidity sensing solutions. This board features the WSEN-HIDS (2525020210001), a MEMS-based capacitive humidity sensor with an integrated ASIC and I2C and SPI serial communication from Würth Elektronik. A silicon-based temperature sensor is also integrated within the same package. ASIC contains the multiplier, operational amplifier, analog-to-digital converter, and other signal conditioning blocks like controller logics and interrupts. It converts the analog signal from humidity and temperature sensing elements into 16-bit digital humidity and temperature values. The 2525020210001 is factory calibrated for both humidity and temperature measurements with no further calibration required. This Click board™ is an ideal solution to be used in various temperature and humidity-related applications.

temphum16_click.png

Click Product page


Click library

  • Author : Nenad Filipovic
  • Date : May 2021.
  • Type : I2C/SPI type

Software Support

We provide a library for the TempHum16 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Library Description

This library contains API for TempHum16 Click driver.

Standard key functions :

  • temphum16_cfg_setup Config Object Initialization function.

    void temphum16_cfg_setup ( temphum16_cfg_t *cfg );
  • temphum16_init Initialization function.

    TEMPHUM16_RETVAL temphum16_init ( temphum16_t *ctx, temphum16_cfg_t *cfg );
  • temphum16_default_cfg Click Default Configuration function.

    void temphum16_default_cfg ( temphum16_t *ctx );

Example key functions :

  • temphum16_check_ready Temp&Hum 16 check ready function.

    uint8_t temphum16_check_ready ( temphum16_t *ctx );
  • temphum16_get_humidity Temp&Hum 16 get humidity function.

    err_t temphum16_get_humidity ( temphum16_t *ctx, float *humidity );
  • temphum16_get_temperature Temp&Hum 16 get temperature function.

    err_t temphum16_get_temperature ( temphum16_t *ctx, float *temperature );

Example Description

This library contains API for the Temp&Hum 16 Click driver. This demo application shows an example of humidity and temperature measurement.

The demo application is composed of two sections :

Application Init

Initialization of SPI or I2C module and log UART. After driver initialization and default settings, the app display retrieves the sensor parameters such as temperature and humidity.


void application_init ( void ) {
    log_cfg_t log_cfg;              /**< Logger config object. */
    temphum16_cfg_t temphum16_cfg;  /**< Click config object. */

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_info( &logger, " Application Init " );

    // Click initialization.

    temphum16_cfg_setup( &temphum16_cfg );
    TEMPHUM16_MAP_MIKROBUS( temphum16_cfg, MIKROBUS_1 );
    err_t init_flag  = temphum16_init( &temphum16, &temphum16_cfg );
    if ( ( init_flag == I2C_MASTER_ERROR ) || ( init_flag == SPI_MASTER_ERROR ) ) {
        log_info( &logger, " Application Init Error. " );
        log_info( &logger, " Please, run program again... " );

        for ( ; ; );
    }

    temphum16_default_cfg ( &temphum16 );
    log_info( &logger, " Application Task " );
    Delay_ms ( 100 );

    temphum16_get_device_id( &temphum16, &device_id );
    log_printf( &logger, "-----------------------\r\n" );
    log_printf( &logger, "  Check communication  \r\n" ); 
    if ( device_id == TEMPHUM16_DEVICE_ID ){
        log_printf( &logger, "      Successful   \r\n" );    
    } else {
        log_printf( &logger, "        Failed     \r\n" );

        for ( ; ; );
    }

    log_printf( &logger, "-----------------------\r\n" );
    log_printf( &logger, "   Start measurements  \r\n" );
    log_printf( &logger, "-----------------------\r\n" );
}

Application Task

This is an example that shows the use of a Temp&Hum 16 Click board™. Logs humidity [ % ] and temperature [ degree Celsius ] data. Results are being sent to the Usart Terminal where you can track their changes.


void application_task ( void ) {
    if ( temphum16_check_ready( &temphum16 ) == TEMPHUM16_DRDY ) {
        temphum16_get_temperature( &temphum16, &temperature );
        log_printf( &logger, " Temperature : %.2f C\r\n", temperature ); 

        temphum16_get_humidity( &temphum16, &humidity );
        log_printf( &logger, " Humidity    : %.2f %%\r\n", humidity ); 
        log_printf( &logger, "-----------------------\r\n" );
        Delay_ms ( 1000 );
    }
}

The full application code, and ready to use projects can be installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Other Mikroe Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.TempHum16

Additional notes and informations

Depending on the development board you are using, you may need USB UART Click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. UART terminal is available in all MikroElektronika compilers.


ALSO FROM THIS AUTHOR

DMA Library

6

DMA is a powerful module that can autonomosly transfer data from memory to memory, memory to peripheral and peripheral to memory thus freeing up processor to do other tasks. This library provides routines for working with DMA module. A special thank you goes out to our valued associate Milos Markovic who helped in creating this package.

[Learn More]

Accel 31 Click

0

Accel 31 Click is a compact add-on board designed for precise motion and orientation detection in space-constrained devices. This board features the BMA580, a triaxial low-g accelerometer from Bosch Sensortec, which offers a 16-bit digital resolution with measurement ranges of ±2, ±4, ±8, and ±16 g, along with flexible output data rates from 1.56Hz to 6.4kHz, enabling high adaptability and accuracy. The BMA580 supports advanced power modes, including high-performance and low-power, self-wake-up functionality, and bone conduction-based voice activity detection.

[Learn More]

Step Up click

5

Step Up Click is a fixed frequency DC-DC step-up (boost) regulator, which can be obtained from any low voltage input - such as NiCd, NiMH or one cell Li-Po/Li-Ion batteries.

[Learn More]