TOP Contributors

  1. MIKROE (2779 codes)
  2. Alcides Ramos (376 codes)
  3. Shawon Shahryiar (307 codes)
  4. jm_palomino (118 codes)
  5. Bugz Bensce (97 codes)
  6. S P (73 codes)
  7. dany (71 codes)
  8. MikroBUS.NET Team (35 codes)
  9. NART SCHINACKOW (34 codes)
  10. Armstrong Subero (27 codes)

Most Downloaded

  1. Timer Calculator (139566 times)
  2. FAT32 Library (72041 times)
  3. Network Ethernet Library (57256 times)
  4. USB Device Library (47615 times)
  5. Network WiFi Library (43219 times)
  6. FT800 Library (42566 times)
  7. GSM click (29930 times)
  8. mikroSDK (28292 times)
  9. PID Library (26933 times)
  10. microSD click (26309 times)
Libstock prefers package manager

Package Manager

We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]

< Back
mikroSDK Library

Load Cell 6 Click

Rating:

0

Author: MIKROE

Last Updated: 2024-10-31

Package Version: 2.1.0.12

mikroSDK Library: 2.0.0.0

Category: Force

Downloaded: 315 times

Not followed.

License: MIT license  

Load Cell 6 Click is a compact add-on board representing a weigh scale solution. This board features the MAX11270, a high-performance 24-bit delta-sigma ADC that achieves excellent 130dB SNR while dissipating an ultra-low 10mW from Maxim Integrated, now part of Analog Devices. This SPI-configurable ADC sample rates up to 64ksps allow precision DC and AC measurements, with integral non-linearity guaranteed to 4ppm maximum. The MAX11270 offers a 6.5nV/√Hz noise programmable gain amplifier with gain settings between 1x to 128x. Optional buffers are also included to isolate the signal inputs from the switched capacitor sampling network, which allows the MAX11270 to be used with high-impedance sources without compromising the available dynamic range.

No Abuse Reported

Do you want to subscribe in order to receive notifications regarding "Load Cell 6 Click" changes.

Do you want to unsubscribe in order to stop receiving notifications regarding "Load Cell 6 Click" changes.

Do you want to report abuse regarding "Load Cell 6 Click".

  • Information
  • Comments (0)

mikroSDK Library Blog


Load Cell 6 Click

Load Cell 6 Click is a compact add-on board representing a weigh scale solution. This board features the MAX11270, a high-performance 24-bit delta-sigma ADC that achieves excellent 130dB SNR while dissipating an ultra-low 10mW from Maxim Integrated, now part of Analog Devices. This SPI-configurable ADC sample rates up to 64ksps allow precision DC and AC measurements, with integral non-linearity guaranteed to 4ppm maximum. The MAX11270 offers a 6.5nV/√Hz noise programmable gain amplifier with gain settings between 1x to 128x. Optional buffers are also included to isolate the signal inputs from the switched capacitor sampling network, which allows the MAX11270 to be used with high-impedance sources without compromising the available dynamic range.

loadcell6_click.png

Click Product page


Click library

  • Author : Nenad Filipovic
  • Date : Oct 2021.
  • Type : SPI type

Software Support

We provide a library for the LoadCell6 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Library Description

This library contains API for LoadCell6 Click driver.

Standard key functions :

  • loadcell6_cfg_setup Config Object Initialization function.

    void loadcell6_cfg_setup ( loadcell6_cfg_t *cfg );
  • loadcell6_init Initialization function.

    err_t loadcell6_init ( loadcell6_t *ctx, loadcell6_cfg_t *cfg );
  • loadcell6_default_cfg Click Default Configuration function.

    err_t loadcell6_default_cfg ( loadcell6_t *ctx );

Example key functions :

  • loadcell6_get_weight Load Cell 6 get weight function.

    err_t loadcell6_get_weight ( loadcell6_t *ctx, loadcell6_data_t *cell_data, float *weight_g );
  • loadcell6_calibration Load Cell 6 calibration function.

    err_t loadcell6_calibration ( loadcell6_t *ctx, uint16_t cal_val, loadcell6_data_t *cell_data );
  • loadcell6_tare Load Cell 6 tare the scales function.

    err_t loadcell6_tare ( loadcell6_t *ctx, loadcell6_data_t *cell_data );

Example Description

This library contains API for the Load Cell 6 Click driver. The library initializes and defines the SPI bus drivers to read status and ADC data. The library also includes a function for tare, calibration and weight measurement.

The demo application is composed of two sections :

Application Init

Initialization of SPI module and log UART. After driver initialization, app performs the power on sets tare the scale, calibrate scale and start measurements.


void application_init ( void )
{
    log_cfg_t log_cfg;  /**< Logger config object. */
    loadcell6_cfg_t loadcell6_cfg;  /**< Click config object. */

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_info( &logger, " Application Init " );

    // Click initialization.
    loadcell6_cfg_setup( &loadcell6_cfg );
    LOADCELL6_MAP_MIKROBUS( loadcell6_cfg, MIKROBUS_1 );
    if ( SPI_MASTER_ERROR == loadcell6_init( &loadcell6, &loadcell6_cfg ) )
    {
        log_error( &logger, " Communication init." );
        for ( ; ; );
    }

    if ( LOADCELL6_ERROR == loadcell6_default_cfg( &loadcell6 ) )
    {
        log_error( &logger, " Default configuration." );
        for ( ; ; );
    }
    Delay_ms ( 1000 );

    log_printf( &logger, "-------------------------\r\n");
    log_printf( &logger, "     Tare the scale :    \r\n");
    log_printf( &logger, "- - - - - - - - - - - - -\r\n");
    log_printf( &logger, " >> Remove all object << \r\n");
    log_printf( &logger, "- - - - - - - - - - - - -\r\n");
    log_printf( &logger, " In the following 10 sec \r\n");
    log_printf( &logger, " please remove all object\r\n");
    log_printf( &logger, "     from the scale.     \r\n");
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );

    log_printf( &logger, "-------------------------\r\n");
    log_printf( &logger, "    Start tare scales    \r\n");
    loadcell6_tare( &loadcell6, &cell_data );
    Delay_ms ( 500 );

    log_printf( &logger, "-------------------------\r\n");
    log_printf( &logger, "   Tarring is complete   \r\n");
    log_printf( &logger, "-------------------------\r\n");
    log_printf( &logger, "    Calibrate Scale :    \r\n");
    log_printf( &logger, "- - - - - - - - - - - - -\r\n");
    log_printf( &logger, "   >>> Load etalon <<<   \r\n");
    log_printf( &logger, "- - - - - - - - - - - - -\r\n");
    log_printf( &logger, " In the following 10 sec \r\n");
    log_printf( &logger, "place 200g weight etalon\r\n");
    log_printf( &logger, "    on the scale for     \r\n");
    log_printf( &logger, "   calibration purpose.  \r\n");
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );

    log_printf( &logger, "-------------------------\r\n");
    log_printf( &logger, "    Start calibration    \r\n");

    if ( LOADCELL6_OK == loadcell6_calibration( &loadcell6, LOADCELL6_WEIGHT_200G, &cell_data )  ) 
    {
        log_printf( &logger, "-------------------------\r\n");
        log_printf( &logger, "    Calibration  Done    \r\n");
        log_printf( &logger, "- - - - - - - - - - - - -\r\n");
        log_printf( &logger, "  >>> Remove etalon <<<  \r\n");
        log_printf( &logger, "- - - - - - - - - - - - -\r\n");
        log_printf( &logger, " In the following 5 sec  \r\n");
        log_printf( &logger, "    remove 200g weight   \r\n");
        log_printf( &logger, "   etalon on the scale.  \r\n");
        Delay_ms ( 1000 );
        Delay_ms ( 1000 );
        Delay_ms ( 1000 );
        Delay_ms ( 1000 );
        Delay_ms ( 1000 );
    }
    else 
    {
        log_printf( &logger, "-------------------------\r\n");
        log_printf( &logger, "   Calibration  Error   \r\n");
        for ( ; ; );
    }

    log_printf( &logger, "-------------------------\r\n");
    log_printf( &logger, "   Start measurements :  \r\n");
    log_printf( &logger, "-------------------------\r\n");
}

Application Task

This is an example that demonstrates the use of the Load Cell 6 Click board™. The Load Cell 6 Click board™ can be used to measure weight and shows the measurement of scales in grams [ g ]. Results are being sent to the Usart Terminal where you can track their changes.


void application_task ( void )
{
    static float weight_g;

    if ( LOADCELL6_OK == loadcell6_get_weight( &loadcell6, &cell_data, &weight_g ) )
    {
        log_printf(&logger, "   Weight : %.2f g\r\n", weight_g ); 
    }
}

The full application code, and ready to use projects can be installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Other Mikroe Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.LoadCell6

Additional notes and informations

Depending on the development board you are using, you may need USB UART Click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all MikroElektronika compilers, or any other terminal application of your choice, can be used to read the message.


ALSO FROM THIS AUTHOR

CAN FD 7 Click

0

CAN FD 7 Click is a compact add-on board that contains a CAN transceiver that supports both CAN and CAN FD protocols. This board features the TCAN1462, an automotive fault-protected CAN FD transceiver from Texas Instruments. It is a high-speed Controller Area Network (CAN) transceiver that meets the ISO 11898-2:2016 high-speed CAN specification and the CiA 601-4 signal improvement capability (SIC) specification.

[Learn More]

Compass 2 click

2

Compass 2 click – board with AK8963 3-axis electronic compass | MikroElektronika Compass 2 click is a mikroBUS add-on board with an AK8963 3-axis electronic compass. The high sensitivity sensor is based on the Hall effect. The built-in ADC converter can be set up at either 14 or 16 bit resolution, for each of the 3 axes.

[Learn More]

GPS2 click - Example

0

Simple example which demonstrates usage of the GPS2 Click board with QUECTEL L30 GPS module. It displays a map of the world on the TFT and shows the location of the GPS module on it.

[Learn More]