TOP Contributors

  1. MIKROE (2784 codes)
  2. Alcides Ramos (385 codes)
  3. Shawon Shahryiar (307 codes)
  4. jm_palomino (118 codes)
  5. Bugz Bensce (97 codes)
  6. S P (73 codes)
  7. dany (71 codes)
  8. MikroBUS.NET Team (35 codes)
  9. NART SCHINACKOW (34 codes)
  10. Armstrong Subero (27 codes)

Most Downloaded

  1. Timer Calculator (139845 times)
  2. FAT32 Library (72209 times)
  3. Network Ethernet Library (57392 times)
  4. USB Device Library (47740 times)
  5. Network WiFi Library (43364 times)
  6. FT800 Library (42700 times)
  7. GSM click (29980 times)
  8. mikroSDK (28440 times)
  9. PID Library (26989 times)
  10. microSD click (26398 times)
Libstock prefers package manager

Package Manager

We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]

< Back
mikroSDK Library

PROFET 10A Click

Rating:

0

Author: MIKROE

Last Updated: 2024-10-31

Package Version: 2.1.0.8

mikroSDK Library: 2.0.0.0

Category: Power Switch

Downloaded: 157 times

Not followed.

License: MIT license  

PROFET Click is a compact add-on board that contains a smart high-side power switch. This board features the BTS7008-1EPA, a single-channel, high-side power switch with embedded protection and diagnosis feature from Infineon Technologies. This switch has a driving capability suitable for 10A loads featuring a ReverSave™, which causes the power transistor to switch on in case of reverse polarity.

No Abuse Reported

Do you want to subscribe in order to receive notifications regarding "PROFET 10A Click" changes.

Do you want to unsubscribe in order to stop receiving notifications regarding "PROFET 10A Click" changes.

Do you want to report abuse regarding "PROFET 10A Click".

  • Information
  • Comments (0)

mikroSDK Library Blog


PROFET 10A Click

PROFET Click is a compact add-on board that contains a smart high-side power switch. This board features the BTS7008-1EPA, a single-channel, high-side power switch with embedded protection and diagnosis feature from Infineon Technologies. This switch has a driving capability suitable for 10A loads featuring a ReverSave™, which causes the power transistor to switch on in case of reverse polarity.

profet10a_click.png

Click Product page


Click library

  • Author : Luka Filipovic
  • Date : Jun 2021.
  • Type : ADC type

Software Support

We provide a library for the PROFET 10A Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Library Description

This library contains API for PROFET 10A Click driver.

Standard key functions :

  • profet10a_cfg_setup Config Object Initialization function.

    void profet10a_cfg_setup ( profet10a_cfg_t *cfg );
  • profet10a_init Initialization function.

    err_t profet10a_init ( profet10a_t *ctx, profet10a_cfg_t *cfg );

Example key functions :

  • profet10a_read_an_pin_voltage PROFET 10A read AN pin voltage level function.

    err_t profet10a_read_an_pin_voltage ( profet10a_t *ctx, float *data_out );
  • profet10a_set_mode PROFET 10A set mode.

    err_t profet10a_set_mode ( profet10a_t *ctx, uint8_t mode );

Example Description

This example showcases the ability of the PROFET 10A Click board. It configures Host MCU for communication and then enables and disables output channel. Besides that, it reads the voltage of IS pin and calculates current on output.

The demo application is composed of two sections :

Application Init

Initialization of the communication modules(ADC and UART) and additional pins for controlling the device.


void application_init ( void )
{
    log_cfg_t log_cfg;  /**< Logger config object. */
    profet10a_cfg_t profet10a_cfg;  /**< Click config object. */

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_info( &logger, " Application Init " );

    // Click initialization.
    profet10a_cfg_setup( &profet10a_cfg );
    PROFET10A_MAP_MIKROBUS( profet10a_cfg, MIKROBUS_1 );
    if ( profet10a_init( &profet10a, &profet10a_cfg ) == ADC_ERROR )
    {
        log_error( &logger, " Application Init Error. " );
        log_info( &logger, " Please, run program again... " );

        for ( ; ; );
    }

    log_info( &logger, " Application Task " );

    profet10a_set_mode( &profet10a, PROFET10A_DIAGNOSTIC_ON );
    Delay_ms ( 1000 );
}

Application Task

On every iteration of the task device switches between DIAGNOSTIC and OFF mode while it reads the voltage of IS pin and with that calculates current on output.


void application_task ( void )
{
    static uint8_t mode = PROFET10A_DIAGNOSTIC_ON;
    float profet10a_an_voltage = 0;

    profet10a_set_mode( &profet10a, mode );

    if ( PROFET10A_DIAGNOSTIC_ON == profet10a.mode )
    {
        mode = PROFET10A_MODE_OFF;
        log_printf( &logger, " > Output ON diagnostic mode\r\n" );
        Delay_ms ( 1000 );
        Delay_ms ( 1000 );
    }
    else
    {
        mode = PROFET10A_DIAGNOSTIC_ON;
        log_printf( &logger, " > Output OFF\r\n" );
    }

    if ( profet10a_read_an_pin_voltage ( &profet10a, &profet10a_an_voltage ) != ADC_ERROR )
    {
        log_printf( &logger, " > IS Voltage \t~ %.3f[V]\r\n", profet10a_an_voltage );

        float current = profet10a_an_voltage * profet10a.kilis / profet10a.rsens;
        log_printf( &logger, " > OUT Current \t~ %.3f[A]\r\n", current );
    }  

    log_printf( &logger, "*******************************************\r\n" );

    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
}

Note

Formula for calculating current on load: I_load = voltage(IS) x kILIS / 1.2 kΩ

The full application code, and ready to use projects can be installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Other Mikroe Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.PROFET10A

Additional notes and informations

Depending on the development board you are using, you may need USB UART Click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. UART terminal is available in all MikroElektronika compilers.


ALSO FROM THIS AUTHOR

Current Limit 9 Click

0

Current Limit 9 Click is a compact add-on board representing a current-limiting solution for your application. This board features the NPS4053, a load switch with a precision adjustable current limit from Nexperia. It is a 5.5V, 55mΩ load switch that allows precise adjustment of the current limit in a range of 110mA up to 2.5A while preserving the constant current during the current limiting.

[Learn More]

NB IoT 2 Click

0

NB IoT 2 Click is a compact add-on board that contains a compact LTE Cat NB2 module with ultra-low power consumption. This board features the BC66-NA, a high-performance, multi-band LTE Cat NB2 module with extremely low power consumption from Quectel Wireless Solutions.

[Learn More]

I2C Isolator 4 Click

0

I2C Isolator 4 Click is a compact add-on board that offers completely isolated bidirectional communication. This board features the MAX14937, a two-channel, 5kVRMS I2C digital isolator from Analog Devices. The MAX14937 provides two bidirectional, open-drain channels for applications that require data to be transmitted in both directions on the same line. It supports data rates from DC up to 1.7MHz and can be used in isolated I2C busses with or without clock stretching.

[Learn More]