TOP Contributors

  1. MIKROE (2657 codes)
  2. Alcides Ramos (355 codes)
  3. Shawon Shahryiar (307 codes)
  4. jm_palomino (112 codes)
  5. Chisanga Mumba (90 codes)
  6. S P (73 codes)
  7. dany (71 codes)
  8. MikroBUS.NET Team (35 codes)
  9. NART SCHINACKOW (34 codes)
  10. Armstrong Subero (27 codes)

Most Downloaded

  1. Timer Calculator (136904 times)
  2. FAT32 Library (70035 times)
  3. Network Ethernet Library (56005 times)
  4. USB Device Library (46308 times)
  5. Network WiFi Library (41934 times)
  6. FT800 Library (41236 times)
  7. GSM click (29024 times)
  8. PID Library (26434 times)
  9. mikroSDK (26402 times)
  10. microSD click (25387 times)
Libstock prefers package manager

Package Manager

We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]

< Back
mikroSDK Library

Air quality 3 click

Rating:

0

Author: MIKROE

Last Updated: 2024-04-03

Package Version: 2.1.0.16

mikroSDK Library: 2.0.0.0

Category: Gas

Downloaded: 258 times

Not followed.

License: MIT license  

Air quality 3 click is the air quality measurement device, which is able to output both equivalent CO2 levels and total volatile organic compounds (TVOC) concentration in the indoor environment.

No Abuse Reported

Do you want to subscribe in order to receive notifications regarding "Air quality 3 click" changes.

Do you want to unsubscribe in order to stop receiving notifications regarding "Air quality 3 click" changes.

Do you want to report abuse regarding "Air quality 3 click".

  • mikroSDK Library 1.0.0.0
  • Comments (0)

mikroSDK Library Blog


Air quality 3 click

Air quality 3 click is the air quality measurement device, which is able to output both equivalent CO2 levels and total volatile organic compounds (TVOC) concentration in the indoor environment.

airquality3_click.png

click Product page


Click library

  • Author : Katarina Perendic
  • Date : okt 2019.
  • Type : I2C type

Software Support

We provide a library for the AirQuality3 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly form compilers IDE(recommended way), or downloaded from our LibStock, or found on mikroE github account.

Library Description

This library contains API for AirQuality3 Click driver.

Standard key functions :

  • Config Object Initialization function.

    void airquality3_cfg_setup ( airquality3_cfg_t *cfg );

  • Initialization function.

    AIRQUALITY3_RETVAL airquality3_init ( airquality3_t ctx, airquality3_cfg_t cfg );

  • Click Default Configuration function.

    void airquality3_default_cfg ( airquality3_t *ctx );

Example key functions :

  • Get CO2 and TVOC data

    uint8_t airquality3_get_co2_and_tvoc ( airquality3_t ctx, airquality3_air_data_t air_data );

  • Temperature and humidity data settings

    void airquality3_set_environment_data ( airquality3_t *ctx, uint32_t env_data );

  • Function for settings sensor drive mode and interrupts.

    void airquality3_set_measurement_mode ( airquality3_t *ctx, uint8_t mode );

Examples Description

The demo application shows air quality measurement.

The demo application is composed of two sections :

Application Init

Configuring clicks and log objects. Settings the click in the default configuration. Call the procedure the wakeup function of the chip.

void application_init ( void )
{
    log_cfg_t log_cfg;
    airquality3_cfg_t cfg;

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_info( &logger, "---- Application Init ----" );

    //  Click initialization.

    airquality3_cfg_setup( &cfg );
    AIRQUALITY3_MAP_MIKROBUS( cfg, MIKROBUS_1 );
    airquality3_init( &airquality3, &cfg );

    // Wake-up click procedure

    airquality3_set_power( &airquality3, AIRQUALITY3_POWER_STATE_ON );
    airquality3_hardware_reset( &airquality3 );
    airquality3_app_function( &airquality3, AIRQUALITY3_APP_START );

    airquality3_default_cfg( &airquality3 );

    Delay_ms ( 500 );
    log_info( &logger, "---- Start measurement ----" );
}

Application Task

Reads CO2 and TVOC value in the air and logs this data on the USBUART.

void application_task ( void )
{
    airquality3_air_data_t air_data;

    //  Task implementation.

    airquality3_get_co2_and_tvoc ( &airquality3, &air_data );
    log_printf( &logger, "\r\n---- AirQuality data ----\r\n" );
    log_printf( &logger, ">> CO2 data is %d ppm.\r\n", air_data.co2 );
    log_printf( &logger, ">> TVOC data is %d ppb.\r\n", air_data.tvoc );

    Delay_1sec();
}

The full application code, and ready to use projects can be installed directly form compilers IDE(recommneded) or found on LibStock page or mikroE GitHub accaunt.

Other mikroE Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.AirQuality3

Additional notes and informations

Depending on the development board you are using, you may need USB UART click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all Mikroelektronika compilers, or any other terminal application of your choice, can be used to read the message.


ALSO FROM THIS AUTHOR

eINK 1.54 inch display

5

This bundle comes with the eINK click adapter and e-Paper display 1.54”. Which provides you an easy start of any project where the e-paper display is needed.

[Learn More]

Relay 5 click

0

Relay 5 Click is a compact add-on board with general-purpose relays that any host MCU can control. This board features three J1031C3VDC.15S, a high-current single-pole double-throw (SPDT) signal relays controlled by the PCA9538A, a low-voltage 8-bit I/O port expander from NXP Semiconductors. Highly sensitive, the J1031C3VDC.15S offers a low coil power consumption in a small, lightweight package with PC pin mounting. It comes with a dimension of 12.5x7.5x10 millimeters (LxWxH) and a 1C contact arrangement with a coil voltage of 3VDC, providing a maximum switching voltage of 125VAC/60VDC.

[Learn More]

Remote Barcode Scanner

0

Simple remote barcode scanner demo application with two devices : - Display node - Scanner node

[Learn More]