TOP Contributors

  1. MIKROE (2656 codes)
  2. Alcides Ramos (353 codes)
  3. Shawon Shahryiar (307 codes)
  4. jm_palomino (112 codes)
  5. Chisanga Mumba (90 codes)
  6. S P (73 codes)
  7. dany (71 codes)
  8. MikroBUS.NET Team (35 codes)
  9. NART SCHINACKOW (34 codes)
  10. Armstrong Subero (27 codes)

Most Downloaded

  1. Timer Calculator (136785 times)
  2. FAT32 Library (69980 times)
  3. Network Ethernet Library (55951 times)
  4. USB Device Library (46274 times)
  5. Network WiFi Library (41889 times)
  6. FT800 Library (41184 times)
  7. GSM click (28988 times)
  8. PID Library (26420 times)
  9. mikroSDK (26374 times)
  10. microSD click (25382 times)
Libstock prefers package manager

Package Manager

We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]

< Back
mikroSDK Library

TempHum 12 click

Rating:

0

Author: MIKROE

Last Updated: 2024-04-03

Package Version: 2.1.0.15

mikroSDK Library: 2.0.0.0

Category: Temperature & humidity

Downloaded: 120 times

Not followed.

License: MIT license  

Temp&Hum 12 click is a smart environmental temperature and humidity sensor Click board™, packed with features which allow easy and simple integration into any design that requires accurate and reliable humidity and temperature measurements.

No Abuse Reported

Do you want to subscribe in order to receive notifications regarding "TempHum 12 click" changes.

Do you want to unsubscribe in order to stop receiving notifications regarding "TempHum 12 click" changes.

Do you want to report abuse regarding "TempHum 12 click".

  • mikroSDK Library 1.0.0.0
  • Comments (0)

mikroSDK Library Blog


Temp&Hum 12 click

Temp&Hum 12 click is a smart environmental temperature and humidity sensor Click board™, packed with features which allow easy and simple integration into any design that requires accurate and reliable humidity and temperature measurements.

temphum12_click.png

click Product page


Click library

  • Author : MikroE Team
  • Date : Dec 2019.
  • Type : I2C type

Software Support

We provide a library for the TempHum12 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly form compilers IDE(recommended way), or downloaded from our LibStock, or found on mikroE github account.

Library Description

This library contains API for TempHum12 Click driver.

Standard key functions :

  • Config Object Initialization function.

    void temphum12_cfg_setup ( temphum12_cfg_t *cfg );

  • Initialization function.

    TEMPHUM12_RETVAL temphum12_init ( temphum12_t ctx, temphum12_cfg_t cfg );

  • Click Default Configuration function.

    void temphum12_default_cfg ( temphum12 *ctx );

Example key functions :

  • Temperature data

    float temphum12_get_temperature ( temphum12_t *ctx, uint8_t temp_in );

  • Relative Huminidy data

    float temphum12_get_humidity ( temphum12_t *ctx );

  • Interrupt state

    uint8_t temphum12_get_intrrupt_state ( temphum12_t *ctx );

Examples Description

This application measures temperature and humidity.

The demo application is composed of two sections :

Application Init

Initializes driver init and configuration device for measurement.


void application_init ( void )
{
    log_cfg_t log_cfg;
    temphum12_cfg_t cfg;
    uint16_t tmp;
    uint8_t read_reg [ 2 ];

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_info( &logger, "---- Application Init ----" );

    //  Click initialization.

    temphum12_cfg_setup( &cfg );
    TEMPHUM12_MAP_MIKROBUS( cfg, MIKROBUS_1 );
    temphum12_init( &temphum12, &cfg );

    temphum12_default_cfg( &temphum12 );

    Delay_ms ( 1000 );
    Delay_ms ( 500 );
    log_printf( &logger, "--- Start measurement ----\r\n" );
}

Application Task

Reads Temperature and Humidity data and this data logs to the USBUART every 1 sec.


void application_task ( void )
{
    float temperature;
    float humidity;

    temperature = temphum12_get_temperature( &temphum12, TEMPHUM12_TEMP_IN_CELSIUS);

    log_printf( &logger, "Temperature: %.2f \r\n", temperature );
    Delay_1sec( );

    humidity = temphum12_get_humidity( &temphum12 );

    log_printf( &logger, "Humidity: %.2f \r\n", humidity );

    log_printf( &logger, "-----------------------------\r\n" );
    Delay_1sec( );
}

The full application code, and ready to use projects can be installed directly form compilers IDE(recommneded) or found on LibStock page or mikroE GitHub accaunt.

Other mikroE Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.TempHum12

Additional notes and informations

Depending on the development board you are using, you may need USB UART click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all Mikroelektronika compilers, or any other terminal application of your choice, can be used to read the message.


ALSO FROM THIS AUTHOR

Dot Matrix R click

5

Dot Matrix R Click is a display device Click board based on a four-digit dot matrix display module, labeled as HCMS-3906. The module holds four 5x7 dot matrices, with very closely spaced, bright red pixel elements. Characters are very clearly displayed as a result.

[Learn More]

Pixi click

0

PIXI™ click is equipped with MAX11300 IC from Maxim Integrated, which features Maxim Integrated's versatile, proprietary PIXI™ technology - it is the industry's first configurable 20-channel mixed-signal data converter. Besides the 12bit multichannel SAR ADC and buffered DAC, it also features one internal and two external temperature sensors for tracking the junction and the environmental temperatures.

[Learn More]

NDIR CO2 click

5

NDIR CO2 click is an advanced integrated CO2 gas sensor system, which is able to measure an absolute CO2 concentration, by utilizing the CDM7160 integrated sensor.

[Learn More]