TOP Contributors

  1. MIKROE (2784 codes)
  2. Alcides Ramos (405 codes)
  3. Shawon Shahryiar (307 codes)
  4. jm_palomino (133 codes)
  5. Bugz Bensce (97 codes)
  6. S P (73 codes)
  7. dany (71 codes)
  8. MikroBUS.NET Team (35 codes)
  9. NART SCHINACKOW (34 codes)
  10. Armstrong Subero (27 codes)

Most Downloaded

  1. Timer Calculator (141815 times)
  2. FAT32 Library (74951 times)
  3. Network Ethernet Library (59306 times)
  4. USB Device Library (49305 times)
  5. Network WiFi Library (45102 times)
  6. FT800 Library (44668 times)
  7. GSM click (31280 times)
  8. mikroSDK (30209 times)
  9. microSD click (27656 times)
  10. PID Library (27562 times)
Libstock prefers package manager

Package Manager

We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]

< Back
mikroSDK Library

Heart rate 3 Click

Rating:

0

Author: MIKROE

Last Updated: 2024-10-31

Package Version: 2.1.0.12

mikroSDK Library: 2.0.0.0

Category: Biometrics

Downloaded: 441 times

Not followed.

License: MIT license  

Heart rate 3 Click is a mikroBUS add-on board whose functionality is determined by two components: an OSRAM’s SFH7050 pulse oximetry and heart rate monitoring module, and a TI AFE4404 (analong-front-end) IC specialized for bio-sensing.

No Abuse Reported

Do you want to subscribe in order to receive notifications regarding "Heart rate 3 Click" changes.

Do you want to unsubscribe in order to stop receiving notifications regarding "Heart rate 3 Click" changes.

Do you want to report abuse regarding "Heart rate 3 Click".

  • mikroSDK Library 1.0.0.0
  • Comments (0)

mikroSDK Library Blog


Heart rate 3 Click

Heart rate 3 Click is a mikroBUS add-on board whose functionality is determined by two components: an OSRAM’s SFH7050 pulse oximetry and heart rate monitoring module, and a TI AFE4404 (analong-front-end) IC specialized for bio-sensing.

heartrate3_click.png

Click Product page


Click library

  • Author : Jova Stajkovic
  • Date : Dec 2019.
  • Type : I2C type

Software Support

We provide a library for the HeartRate3 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly form compilers IDE(recommended way), or downloaded from our LibStock, or found on mikroE github account.

Library Description

This library contains API for HeartRate3 Click driver.

Standard key functions :

  • heartrate3_cfg_setup Config Object Initialization function.

    void heartrate3_cfg_setup ( heartrate3_cfg_t *cfg ); 
  • heartrate3_init Initialization function.

    err_t heartrate3_init ( heartrate3_t *ctx, heartrate3_cfg_t *cfg );
  • heartrate3_default_cfg Click Default Configuration function.

    err_t heartrate3_default_cfg ( heartrate3_t *ctx );

Example key functions :

  • heartrate3_check_data_ready Function is used to check data ready flag.

    uint8_t heartrate3_check_data_ready ( heartrate3_t *ctx );
  • heartrate3_write_data Function is used to write 32-bit data into register.

    err_t heartrate3_write_data ( heartrate3_t *ctx, uint8_t reg_adr, uint32_t wr_data );
  • heartrate3_read_24bit Function is used to read 24-bit value from register.

    err_t heartrate3_read_24bit ( heartrate3_t *ctx, uint8_t reg_adr, uint32_t *data_out );

Examples Description

The demo application shows reflected red, green and ir values.

The demo application is composed of two sections :

Application Init

Initalizes Click driver, resets the device, applies default settings and makes an initial log.


void application_init ( void )
{
    log_cfg_t log_cfg;
    heartrate3_cfg_t heartrate3_cfg;

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_info( &logger, "---- Application Init ----" );

    //  Click initialization.
    heartrate3_cfg_setup( &heartrate3_cfg );
    HEARTRATE3_MAP_MIKROBUS( heartrate3_cfg, MIKROBUS_1 );
    if ( I2C_MASTER_ERROR == heartrate3_init( &heartrate3, &heartrate3_cfg ) ) 
    {
        log_error( &logger, " Communication init." );
        for ( ; ; );
    }

    log_printf( &logger, "----------------------\r\n" );
    log_printf( &logger, "  Heart rate 3 Click  \r\n" );
    log_printf( &logger, "----------------------\r\n" );

    if ( HEARTRATE3_ERROR == heartrate3_default_cfg ( &heartrate3 ) )
    {
        log_error( &logger, " Default configuration." );
        for ( ; ; );
    }

    log_printf( &logger, "     Initialised!     \r\n" );
    log_printf( &logger, "----------------------\r\n" );    
    log_info( &logger, " Application Task " );
    Delay_ms ( 100 );
}

Application Task

This example demonstrates the use of Heart rate 3 board. It is set in default mode, and reads reflected red, green and ir values and displays the results on USART terminal.


void application_task ( void )
{
    err_t error_flag = HEARTRATE3_OK;
    if ( heartrate3_check_data_ready ( &heartrate3 ) )
    {
        error_flag |= heartrate3_read_24bit( &heartrate3, HEARTRATE3_REG_LED2VAL, &led_2 );
        error_flag |= heartrate3_read_24bit( &heartrate3, HEARTRATE3_REG_ALED2VAL, &aled_2 );
        error_flag |= heartrate3_read_24bit( &heartrate3, HEARTRATE3_REG_LED1VAL, &led_1 );
        error_flag |= heartrate3_read_24bit( &heartrate3, HEARTRATE3_REG_ALED1VAL, &aled_1 );
        error_flag |= heartrate3_read_24bit( &heartrate3, HEARTRATE3_REG_LED2_ALED2VAL, &led_2_aled_2 );
        error_flag |= heartrate3_read_24bit( &heartrate3, HEARTRATE3_REG_LED1_ALED1VAL, &led_1_aled_1 );
        if ( HEARTRATE3_OK == error_flag )
        {
            log_printf( &logger, "%lu;%lu;%lu;%lu;%lu;%lu;\r\n", 
                        led_2, aled_2, led_1, aled_1, led_2_aled_2, led_1_aled_1 );
        }
    }
}  

Note

We recommend using the SerialPlot tool for data visualizing.

The full application code, and ready to use projects can be installed directly form compilers IDE(recommneded) or found on LibStock page or mikroE GitHub accaunt.

Other mikroE Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.HeartRate3

Additional notes and informations

Depending on the development board you are using, you may need USB UART Click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all Mikroelektronika compilers, or any other terminal application of your choice, can be used to read the message.


ALSO FROM THIS AUTHOR

Multi Stepper TB67S102 Click

0

Multi Stepper Click is a compact add-on board that contains a bipolar stepper motor driver. This board features the TB67S102AFNG, CLOCK-in controlled bipolar stepping motor driver from Toshiba Semiconductor. It supports a PWM constant-current control drive and allows full-, half-, and quarter-step operation for less motor noise and smoother control. It has a wide operating voltage range of 10V to 47V with an output current capacity of 2.8A in addition to several built-in error detection circuits.

[Learn More]

8x8 click - Example

0

Simple example which demonstrates working with 8x8 click boards. 8x8 clicks are 8x8 LED matrix displays in form of add-on boards in mikroBUS form factor. Boards feature MAX7219 8-digit LED display driver module as well as 64 LED diodes.

[Learn More]

Power/Reset click

5

Power/Reset Click is equipped with two capacitive touch pads on a single click boardâ„¢. It can be activated by touch, and unlike the mechanical button, the capacitive touch button lasts much longer, it is not prone to damage and wear over time and it is very reliable.

[Learn More]