We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]
Rating:
Author: MIKROE
Last Updated: 2021-01-18
Package Version: 1.0.0.0
mikroSDK Library: 1.0.0.0
Category: SPI
Downloaded: 2257 times
Not followed.
License: MIT license
SPI Isolator 2 Click is a compact add-on board that contains a digital isolator optimized for a serial peripheral interface.
Do you want to subscribe in order to receive notifications regarding "SPI Isolator 2 click" changes.
Do you want to unsubscribe in order to stop receiving notifications regarding "SPI Isolator 2 click" changes.
Do you want to report abuse regarding "SPI Isolator 2 click".
Library Description
The library covers all the necessary functions to control SPI Isolator 2 Click board™. Library performs a standard SPI interface communication.
Key functions:
void spiisolator2_output_enable ( uint8_t en_out )
- Output enable function.int8_t addr_n_bytes, uint8_t *p_tx_data, uint8_t tx_data_n_bytes )
- Multi write function.uint8_t addr_n_bytes, uint8_t *p_rx_data, uint8_t tx_data_n_bytes )
- Multi read function.Examples description
The application is composed of three sections :
void application_task ( )
{
spiisolator2_set_cmd( SPIISOLATOR2_EEPROM5_CMD_WRITE_ENABLE );
Delay_ms( 10 );
spiisolator2_multi_write( SPIISOLATOR2_EEPROM5_CMD_WRITE | memory_address,
4,
&demo_data[ 0 ],
9 );
mikrobus_logWrite( " Write data : ", _LOG_TEXT );
for ( n_cnt = 0; n_cnt < 9; n_cnt++ )
{
mikrobus_logWrite( &demo_data[ n_cnt ], _LOG_BYTE );
}
mikrobus_logWrite( "- - - - - - - - - - - ", _LOG_LINE );
Delay_ms( 100 );
mikrobus_logWrite( " Read data : ", _LOG_TEXT );
spiisolator2_multi_read( SPIISOLATOR2_EEPROM5_CMD_READ | memory_address,
4,
&read_data[ 0 ],
9 );
Delay_ms( 1000 );
for ( n_cnt = 0; n_cnt < 9; n_cnt++ )
{
mikrobus_logWrite( &read_data[ n_cnt ], _LOG_BYTE );
}
mikrobus_logWrite( "----------------------", _LOG_LINE );
Delay_ms( 5000 );
}
Other Mikroe Libraries used in the example:
Additional notes and informations
Depending on the development board you are using, you may need USB UART click, USB UART 2 click or RS232 click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all MikroElektronika compilers, or any other terminal application of your choice, can be used to read the message.