TOP Contributors

  1. MIKROE (2784 codes)
  2. Alcides Ramos (387 codes)
  3. Shawon Shahryiar (307 codes)
  4. jm_palomino (120 codes)
  5. Bugz Bensce (97 codes)
  6. S P (73 codes)
  7. dany (71 codes)
  8. MikroBUS.NET Team (35 codes)
  9. NART SCHINACKOW (34 codes)
  10. Armstrong Subero (27 codes)

Most Downloaded

  1. Timer Calculator (140169 times)
  2. FAT32 Library (72625 times)
  3. Network Ethernet Library (57645 times)
  4. USB Device Library (47958 times)
  5. Network WiFi Library (43555 times)
  6. FT800 Library (42942 times)
  7. GSM click (30141 times)
  8. mikroSDK (28672 times)
  9. PID Library (27058 times)
  10. microSD click (26553 times)
Libstock prefers package manager

Package Manager

We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]

< Back
mikroSDK Library

AD-SWIO click

Rating:

5

Author: MIKROE

Last Updated: 2020-04-22

Package Version: 1.0.0.0

mikroSDK Library: 1.0.0.0

Category: ADC

Downloaded: 3269 times

Not followed.

License: MIT license  

AD-SWIO Click is a quad-channel software configurable input/output solution based on AD74412R, for building and process control application. The AD74412R is a quad-channel software configurable input/output solution for building and process control applications.

No Abuse Reported

Do you want to subscribe in order to receive notifications regarding "AD-SWIO click" changes.

Do you want to unsubscribe in order to stop receiving notifications regarding "AD-SWIO click" changes.

Do you want to report abuse regarding "AD-SWIO click".

  • mikroSDK Library 2.0.0.0
  • Comments (0)
DOWNLOAD LINK RELATED COMPILER CONTAINS
mikroBasic PRO for ARM
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroBasic PRO for AVR
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroBasic PRO for dsPIC30/33 & PIC24
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroBasic PRO for FT90x
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroBasic PRO for PIC
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroBasic PRO for PIC32
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroC PRO for ARM
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroC PRO for AVR
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroC PRO for dsPIC30/33 & PIC24
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroC PRO for FT90x
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroC PRO for PIC
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroC PRO for PIC32
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroPascal PRO for ARM
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroPascal PRO for AVR
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroPascal PRO for dsPIC30/33 & PIC24
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroPascal PRO for FT90x
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroPascal PRO for PIC
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroPascal PRO for PIC32
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc

mikroSDK Library Blog

AD-SWIO Click

AD-SWIO Click

Native view of the AD-SWIO Click board.

View full image
AD-SWIO Click

AD-SWIO Click

Front and back view of the AD-SWIO Click board.

View full image

Library Description

This library has ability to perform a full control of the AD-SWIO Click board. This click can convert and measure voltage, current and resistance from 4 independent channels and 4 different diagnostics.

Key functions:

  • adswio_err_t adswio_enable_ch( uint8_t channel ) - This function allows user to enable the desired channel/channels.
  • adswio_err_t adswio_set_ch_func( uint8_t channel, uint8_t ch_func ) - This function allows user to modify the functionality of the selected channel.
  • adswio_err_t adswio_get_conv_results( uint8_t channel, uint16_t *data_out ) - This function allows user to get the converted results of the selected channel.

Examples description

The application is composed of three sections :

  • System Initialization - Initializes all necessary peripherals and pins used for this click. Also initializes uart console module.
  • Application Initialization - Performs a hardware reset of the click board and executes a default configuration which includes that channel A will be enabled to measure voltage input in the range from 0V to 10V, with 4k8 SPS sample rating. In this function also Silicon Revision ID will be checked.
  • Application Task - (code snippet) - Waits until data from the enabled channel is ready and then reads results of conversion for channel A and if response is ok, prints the results on the uart console.
void application_task( )
{
    adswio_rdy = adswio_status_pin_ready( );

    while ( adswio_rdy == 0 )
    {
        adswio_rdy = adswio_status_pin_ready( );
    }

    adswio_err = adswio_get_conv_results( _ADSWIO_SETUP_CONV_EN_CHA,
                                          &adswio_ch_a );

    if ( adswio_err == _ADSWIO_ERR_STATUS_OK )
    {
        adswio_res = adswio_ch_a;
        adswio_res /= _ADSWIO_RANGE_RESOLUTION;
        adswio_res *= _ADSWIO_RANGE_VOLT_MV;
        adswio_ch_a = adswio_res;

        WordToStr( adswio_ch_a, adswio_log );
        Ltrim( adswio_log );

        mikrobus_logWrite( "* CH A converted result is ", _LOG_TEXT );
        mikrobus_logWrite( adswio_log, _LOG_TEXT );
        mikrobus_logWrite( " mV", _LOG_LINE );
        Delay_ms( 100 );
    }
}


Additional Functions :

  • Application Default Handler - Used to send error report messages from click driver to initialized console module.

Other mikroE Libraries used in the example:

  • Conversions
  • C_String
  • SPI
  • UART

Additional notes and informations

Depending on the development board you are using, you may need USB UART clickUSB UART 2 click or RS232 click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all MikroElektronika compilers, or any other terminal application of your choice, can be used to read the message.

ALSO FROM THIS AUTHOR

2x20W Amp click

6

2x20W Amp click carries the MAX9744 stereo class D audio power amplifier from Maxim Integrated. This click brings the Class AB sound performance with Class D efficiency. The perfect combination for your speakers.

[Learn More]

ECG 3 click

6

ECG 3 click is a complete solution for the development of ECG applications, which utilizes a specialized clinical-grade biopotential analog front-end (AFE) IC. ECG 3 click is an ideal solution for the development of heart rate monitoring applications, fitness applications, for the ECG bio-authentication, and similar applications.

[Learn More]

Heart Rate 5 Click

0

Heart Rate 5 Click is the optical biosensor Click board™ which can be used for the heart-rate monitoring (HRM), as well as the peripheral capillary oxygen saturation monitoring (SpO2). This Click board™ employs a very sensitive analog front-end IC with high dynamic range, which ensures accurate and reliable readings.

[Learn More]