THERMO Click features the MAX31855K thermocouple-to-digital converter as well as PCC-SMP connector for K-type thermocouple probes. The Click is designed to run on a 3.3V power supply.
Do you want to subscribe in order to receive notifications regarding "THERMO Click" changes.
Do you want to unsubscribe in order to stop receiving notifications regarding "THERMO Click" changes.
Do you want to report abuse regarding "THERMO Click".
DOWNLOAD LINK | RELATED COMPILER | CONTAINS |
---|---|---|
3422_thermo_click.zip [420.73KB] | mikroC AI for ARM GCC for ARM Clang for ARM mikroC AI for PIC mikroC AI for PIC32 XC32 GCC for RISC-V Clang for RISC-V mikroC AI for AVR mikroC AI for dsPIC XC16 |
|
THERMO Click features the MAX31855K thermocouple-to-digital converter as well as PCC-SMP connector for K-type thermocouple probes. The Click is designed to run on a 3.3V power supply.
We provide a library for the Thermo Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.
Package can be downloaded/installed directly form compilers IDE(recommended way), or downloaded from our LibStock, or found on mikroE github account.
This library contains API for Thermo Click driver.
Config Object Initialization function.
void thermo_cfg_setup ( thermo_cfg_t *cfg );
Initialization function.
THERMO_RETVAL thermo_init ( thermo_t ctx, thermo_cfg_t cfg );
Function gets thermocouple temperature data.
float thermo_get_temperature ( thermo_t* ctx );
Function checks fault states of MAX31855 sensor on Thermo Click board.
uint8_t thermo_check_fault ( thermo_t* ctx );
Function reads the 32-bit of data from the sensor.
uint32_t thermo_read_data ( thermo_t* ctx );
This example measures temperature and then logs the results.
The demo application is composed of two sections :
Initializes driver and start write log.
void application_init ( void )
{
log_cfg_t log_cfg;
thermo_cfg_t cfg;
/**
* Logger initialization.
* Default baud rate: 115200
* Default log level: LOG_LEVEL_DEBUG
* @note If USB_UART_RX and USB_UART_TX
* are defined as HAL_PIN_NC, you will
* need to define them manually for log to work.
* See @b LOG_MAP_USB_UART macro definition for detailed explanation.
*/
LOG_MAP_USB_UART( log_cfg );
log_init( &logger, &log_cfg );
log_info( &logger, "---- Application Init ----" );
thermo_cfg_setup( &cfg );
THERMO_MAP_MIKROBUS( cfg, MIKROBUS_1 );
thermo_init( &thermo, &cfg );
if ( thermo_check_fault( &thermo ) )
{
display_error_msg();
}
else
{
log_printf( &logger, "Status OK\r\n" );
}
}
Temperature measured by the thermocouple is converter and the results are logged.
void application_task ( void )
{
temperature = thermo_get_temperature( &thermo );
log_printf( &logger, "Temperature : %f\r\n", temperature );
}
The full application code, and ready to use projects can be installed directly form compilers IDE(recommneded) or found on LibStock page or mikroE GitHub accaunt.
Other mikroE Libraries used in the example:
Additional notes and informations
Depending on the development board you are using, you may need USB UART Click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all Mikroelektronika compilers, or any other terminal application of your choice, can be used to read the message.