TOP Contributors

  1. MIKROE (2762 codes)
  2. Alcides Ramos (374 codes)
  3. Shawon Shahryiar (307 codes)
  4. jm_palomino (118 codes)
  5. Bugz Bensce (90 codes)
  6. S P (73 codes)
  7. dany (71 codes)
  8. MikroBUS.NET Team (35 codes)
  9. NART SCHINACKOW (34 codes)
  10. Armstrong Subero (27 codes)

Most Downloaded

  1. Timer Calculator (139250 times)
  2. FAT32 Library (71747 times)
  3. Network Ethernet Library (57120 times)
  4. USB Device Library (47430 times)
  5. Network WiFi Library (43082 times)
  6. FT800 Library (42403 times)
  7. GSM click (29835 times)
  8. mikroSDK (28074 times)
  9. PID Library (26885 times)
  10. microSD click (26198 times)
Libstock prefers package manager

Package Manager

We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]

< Back
mikroSDK Library

Thermo 13 Click

Rating:

0

Author: MIKROE

Last Updated: 2024-10-31

Package Version: 2.1.0.17

mikroSDK Library: 2.0.0.0

Category: Temperature & humidity

Downloaded: 255 times

Not followed.

License: MIT license  

Thermo 13 Click is a Click board™ equipped with the sensor IC, which can digitize temperature measurements between -30°C and +95°C so that the temperature measurement data can be processed by the host MCU.

No Abuse Reported

Do you want to subscribe in order to receive notifications regarding "Thermo 13 Click" changes.

Do you want to unsubscribe in order to stop receiving notifications regarding "Thermo 13 Click" changes.

Do you want to report abuse regarding "Thermo 13 Click".

  • mikroSDK Library 1.0.0.0
  • Comments (0)

mikroSDK Library Blog


Thermo 13 Click

Thermo 13 Click is a Click board™ equipped with the sensor IC, which can digitize temperature measurements between -30°C and +95°C so that the temperature measurement data can be processed by the host MCU.

thermo13_click.png

Click Product page


Click library

  • Author : MikroE Team
  • Date : Dec 2019.
  • Type : I2C type

Software Support

We provide a library for the Thermo13 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly form compilers IDE(recommended way), or downloaded from our LibStock, or found on mikroE github account.

Library Description

This library contains API for Thermo13 Click driver.

Standard key functions :

  • Config Object Initialization function.

    void thermo13_cfg_setup ( thermo13_cfg_t *cfg );

  • Initialization function.

    THERMO13_RETVAL thermo13_init ( thermo13_t ctx, thermo13_cfg_t cfg );

  • Click Default Configuration function.

    void thermo13_default_cfg ( thermo13_t *ctx );

Example key functions :

  • Set temperature limit register

    void thermo13_set_temp_limit ( thermo13_t *ctx, uint8_t temp_reg, float temp );

  • Get temperature register

    float thermo13_get_temp_limit ( thermo13_t *ctx, uint8_t temp_reg );

  • Ambient temperature data

    float thermo13_get_ambient_temperature_data ( thermo13_t *ctx, uint8_t temp_in );

Examples Description

The application measures temperature

The demo application is composed of two sections :

Application Init

Initializes the driver init, configures the module and reads the temperature Limit LOW/HIGH values that are set.


void application_init ( void )
{
    log_cfg_t log_cfg;
    thermo13_cfg_t cfg;

    float temp_limit_low;
    float temp_limit_high;

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_info( &logger, "---- Application Init ----" );

    //  Click initialization

    thermo13_cfg_setup( &cfg );
    THERMO13_MAP_MIKROBUS( cfg, MIKROBUS_1 );
    thermo13_init( &thermo13, &cfg );

    // Configuration 

    thermo13_configuration( &thermo13, THERMO13_CFG_CONTINUOUS_MEASUREMENT |
                            THERMO13_CFG_FAULT_QUEUE_1 |
                            THERMO13_CFG_ALERT_ACTIVE_HIGH |
                            THERMO13_CFG_INTERRUPT_IS_ACTIVE |
                            THERMO13_CFG_WAIT_TIME_X16 );


    // Temperature Register
    log_printf( &logger, " --- Temperature register data --- \r\n \r\n" );

    temp_limit_low = thermo13_get_temp_limit ( &thermo13, THERMO13_REG_TEMPERATURE_LIMIT_LOW );
    log_printf( &logger, " --- Temp - Limit LOW : %.2f C \r\n ", temp_limit_low );

    temp_limit_high = thermo13_get_temp_limit ( &thermo13, THERMO13_REG_TEMPERATURE_LIMIT_HIGH );
    log_printf( &logger, " --- Temp - Limit HIGH :  %.2f C \r\n \r\n  ", temp_limit_high );

    log_printf( &logger, " --- Ambient temperature measurement --- \r\n " );

}
}

Application Task

Reads ambient temperature data and this data logs to USBUART every 1500ms.


void application_task ( void )
{
    float temperature;

    temperature = thermo13_get_ambient_temperature_data ( &thermo13,  THERMO13_TEMP_IN_CELSIUS );

    log_printf( &logger, "** temperature %.2f ** \r\n" );

    log_printf( &logger, " ----------------------------\r\n" );

    Delay_ms ( 1000 );
    Delay_ms ( 500 );
}

The full application code, and ready to use projects can be installed directly form compilers IDE(recommneded) or found on LibStock page or mikroE GitHub accaunt.

Other mikroE Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.Thermo13

Additional notes and informations

Depending on the development board you are using, you may need USB UART Click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all Mikroelektronika compilers, or any other terminal application of your choice, can be used to read the message.


ALSO FROM THIS AUTHOR

Weather click

2

Weather click carries the BME280 integrated environmental unit from Bosch. It’s a sensor that detects humidity, pressure and temperature.Weather click can communicate with the target MCU either through mikroBUS SPI or I2C interfaces. The board is designed to use a 3.3V power supply.

[Learn More]

6DOF IMU 3 click

5

The 6 DOF IMU 3 Click is a Click board equipped with the FXOS8700CQ 6-axis sensor with integrated linear accelerometer and magnetometer.

[Learn More]

Pressure 10 click

5

Pressure 10 Click features a digital interface barometric pressure sensor, labeled as HSPPAD042A. Barometric pressure is detected by the MEMS sensor that is placed on this Click boardâ„¢ using the piezoresistive bridge circuit formed on the silicon diaphragm.

[Learn More]