TOP Contributors

  1. MIKROE (2784 codes)
  2. Alcides Ramos (405 codes)
  3. Shawon Shahryiar (307 codes)
  4. jm_palomino (133 codes)
  5. Bugz Bensce (97 codes)
  6. S P (73 codes)
  7. dany (71 codes)
  8. MikroBUS.NET Team (35 codes)
  9. NART SCHINACKOW (34 codes)
  10. Armstrong Subero (27 codes)

Most Downloaded

  1. Timer Calculator (142070 times)
  2. FAT32 Library (75298 times)
  3. Network Ethernet Library (59494 times)
  4. USB Device Library (49524 times)
  5. Network WiFi Library (45288 times)
  6. FT800 Library (44915 times)
  7. GSM click (31433 times)
  8. mikroSDK (30452 times)
  9. microSD click (27802 times)
  10. PID Library (27624 times)
Libstock prefers package manager

Package Manager

We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]

< Back
mikroSDK Library

Thermo 7 Click

Rating:

0

Author: MIKROE

Last Updated: 2024-10-31

Package Version: 2.1.0.16

mikroSDK Library: 2.0.0.0

Category: Temperature & humidity

Downloaded: 422 times

Not followed.

License: MIT license  

Thermo 7 Click is a Click board™ equipped with the sensor IC, which can digitize temperature measurements between -55°C and +125°C so that the temperature measurement data can be processed by the host MCU.

No Abuse Reported

Do you want to subscribe in order to receive notifications regarding "Thermo 7 Click" changes.

Do you want to unsubscribe in order to stop receiving notifications regarding "Thermo 7 Click" changes.

Do you want to report abuse regarding "Thermo 7 Click".

  • mikroSDK Library 1.0.0.0
  • Comments (0)

mikroSDK Library Blog


Thermo 7 Click

Thermo 7 Click is a Click board™ equipped with the sensor IC, which can digitize temperature measurements between -55°C and +125°C so that the temperature measurement data can be processed by the host MCU.

thermo7_click.png

Click Product page


Click library

  • Author : MikroE Team
  • Date : Dec 2019.
  • Type : I2C type

Software Support

We provide a library for the Thermo7 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly form compilers IDE(recommended way), or downloaded from our LibStock, or found on mikroE github account.

Library Description

This library contains API for Thermo7 Click driver.

Standard key functions :

  • Config Object Initialization function.

    void thermo7_cfg_setup ( thermo7_cfg_t *cfg );

  • Initialization function.

    THERMO7_RETVAL thermo7_init ( thermo7_t ctx, thermo7_cfg_t cfg );

  • Click Default Configuration function.

    void thermo7_default_cfg ( thermo7_t *ctx );

Example key functions :

  • This fuction gets Hysteresis Temperature.

    int16_t thermo7_get_hysteresis_temperature ( thermo7_t *ctx );

  • This fuction sets limit temperature.

    void thermo7_set_limit_temperature ( thermo7_t *ctx, int16_t temperature );

  • This fuction reads state of interrupt pins.

    uint8_t thermo7_get_interrupt ( thermo7_t *ctx );

Examples Description

This application reads ambient temperature.

The demo application is composed of two sections :

Application Init

Initializes device.


void application_init ( void )
{
    log_cfg_t log_cfg;
    thermo7_cfg_t cfg;

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_info( &logger, "---- Application Init ----\r\n" );

    //  Click initialization.

    thermo7_cfg_setup( &cfg );
    THERMO7_MAP_MIKROBUS( cfg, MIKROBUS_1 );
    thermo7_init( &thermo7, &cfg );

    thermo7_set_configuration( &thermo7, THERMO7_CONFIG_COMPARATOR_MODE | THERMO7_CONFIG_ALERT_POLARITY_ACTIVE_HIGH );
    thermo7_set_resolution( &thermo7, THERMO7_CONFIG_ADC_RESOLUTION_12bit );
}

Application Task

Reads ambient temperature and logs to USBUART every 1 seconds.


void application_task ( void )
{
    float ambient_temperature;

    ambient_temperature = thermo7_read_ambient_temperature( &thermo7 );
    log_printf( &logger, " Ambient temperature : %f �C\r\n", ambient_temperature );

    Delay_ms ( 1000 );
}

The full application code, and ready to use projects can be installed directly form compilers IDE(recommneded) or found on LibStock page or mikroE GitHub accaunt.

Other mikroE Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.Thermo7

Additional notes and informations

Depending on the development board you are using, you may need USB UART Click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all Mikroelektronika compilers, or any other terminal application of your choice, can be used to read the message.


ALSO FROM THIS AUTHOR

WebcamSurveillance

10

This project shows how you can build your own simple surveillance system, using Network Ethernet Internal Library.

[Learn More]

Matrix R Click

0

Matrix R Click is a mikroBUS add-on board with two red 5x7 matrices driven by two MAX7219 8-bit LED Display Drivers. The active area of each matrix is 7.62mm high and 5.08 mm wide. 7x5 is a standard resolution for displaying ASCII characters, so the Click is essentially a dual-character display capable of showing letters in more readable typefaces compared to a 14-segment display. The Click communicates with the target MCU through the mikroBUS:tm: SPI interface with two separate Chip Select lines for each matrix (CSL for the left, CSR for the right). This board is designed to use a 5V power supply.

[Learn More]

I2C 1-Wire click

5

This example shows ID numbers from Unique ID Click and several Thermo Sensors (DS1820), connected on each channel. If there is no device detected on the channel, warning note is shown on TFT.

[Learn More]