TOP Contributors

  1. MIKROE (2784 codes)
  2. Alcides Ramos (405 codes)
  3. Shawon Shahryiar (307 codes)
  4. jm_palomino (133 codes)
  5. Bugz Bensce (97 codes)
  6. S P (73 codes)
  7. dany (71 codes)
  8. MikroBUS.NET Team (35 codes)
  9. NART SCHINACKOW (34 codes)
  10. Armstrong Subero (27 codes)

Most Downloaded

  1. Timer Calculator (141803 times)
  2. FAT32 Library (74940 times)
  3. Network Ethernet Library (59303 times)
  4. USB Device Library (49298 times)
  5. Network WiFi Library (45094 times)
  6. FT800 Library (44656 times)
  7. GSM click (31275 times)
  8. mikroSDK (30205 times)
  9. microSD click (27654 times)
  10. PID Library (27561 times)
Libstock prefers package manager

Package Manager

We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]

< Back
mikroSDK Library

MCP2542 Click

Rating:

0

Author: MIKROE

Last Updated: 2024-10-31

Package Version: 2.1.0.12

mikroSDK Library: 2.0.0.0

Category: CAN

Downloaded: 400 times

Not followed.

License: MIT license  

This application use for comunication

No Abuse Reported

Do you want to subscribe in order to receive notifications regarding "MCP2542 Click" changes.

Do you want to unsubscribe in order to stop receiving notifications regarding "MCP2542 Click" changes.

Do you want to report abuse regarding "MCP2542 Click".

  • mikroSDK Library 1.0.0.0
  • Comments (0)

mikroSDK Library Blog


MCP2542 Click

MCP2542 Click is the CAN bus transceiver, which allows TTL/CMOS level signals typically found on MCUs, to be used for the communication via the CAN bus, which uses the higher voltage levels and differential signals

mcp2542_click.png

Click Product page


Click library

  • Author : MikroE Team
  • Date : Dec 2019.
  • Type : UART type

Software Support

We provide a library for the Mcp2542 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly form compilers IDE(recommended way), or downloaded from our LibStock, or found on mikroE github account.

Library Description

This library contains API for Mcp2542 Click driver.

Standard key functions :

  • Config Object Initialization function.

    void mcp2542_cfg_setup ( mcp2542_cfg_t *cfg );

  • Initialization function.

    MCP2542_RETVAL mcp2542_init ( mcp2542_t ctx, mcp2542_cfg_t cfg );

  • Click Default Configuration function.

    void mcp2542_default_cfg( mcp2542_t *ctx );

Example key functions :

  • Generic single read function.

    mcp2542_data_t mcp2542_generic_single_read ( mcp2542_t *ctx );

  • Generic single write function.

    void mcp2542_generic_single_write ( mcp2542_t *ctx, mcp2542_data_t tx_data );

  • Generic multi write function.

    void mcp2542_generic_multi_write ( mcp2542_t ctx, mcp2542_data_t data_buf, uart_length_t len );

Examples Description

This application use for comunication.

The demo application is composed of two sections :

Application Init

Driver intialization.


void application_init ( void )
{
    log_cfg_t log_cfg;
    mcp2542_cfg_t cfg;

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_info( &logger, "---- Application Init ----" );

    //  Click initialization.

    mcp2542_cfg_setup( &cfg );
    MCP2542_MAP_MIKROBUS( cfg, MIKROBUS_1 );
    mcp2542_init( &mcp2542, &cfg );

     mcp2542_default_cfg( &mcp2542 );
}

Application Task

Checks if new data byte have received in rx buffer (ready for reading), and if ready than reads one byte from rx buffer. In second case aplication task writes message data via UART.


void application_task ( void )
{
    uint8_t tmp;

    //  Task implementation.

#ifdef DEMO_APP_RECEIVER

       // RECEIVER - UART polling

       tmp =  mcp2542_generic_single_read( &mcp2542 );
       log_write( &logger, &tmp, LOG_FORMAT_BYTE );
#endif
#ifdef DEMO_APP_TRANSMITER

       // TRANSMITER - TX each 2 sec

       mcp2542_generic_multi_write( &mcp2542, demo_message, 9 );
       Delay_ms ( 1000 );
       Delay_ms ( 1000 );
#endif

}  

The full application code, and ready to use projects can be installed directly form compilers IDE(recommneded) or found on LibStock page or mikroE GitHub accaunt.

Other mikroE Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.Mcp2542

Additional notes and informations

Depending on the development board you are using, you may need USB UART Click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all Mikroelektronika compilers, or any other terminal application of your choice, can be used to read the message.


ALSO FROM THIS AUTHOR

3D Hall 7 click

5

3D HALL 7 click is a very accurate, magnetic field sensing Click board, used to measure the intensity of the magnetic field across three perpendicular axes.

[Learn More]

USB MUX Click

0

USB MUX Click is a compact add-on board with a high-bandwidth switch designed for switching and isolating high-speed USB 2.0 signals in systems with limited USB I/Os. This board features the TS3USB30E, a USB 2.0 1:2 multiplexer/demultiplexer switch with a single enable from Texas Instruments.

[Learn More]

Stepper 4 Click

0

Stepper 4 Click is a very versatile bipolar stepping motor driver. It features TB67S269FTG IC, fabricated with the BiCD process, allowing the Click board™ to handle significant voltage and current levels up to 35V and 1.2A. This IC has the integrated translator section, used to simplify the control: using simple step control inputs from the host MCU, the stepper motor can be driven in both directions, with the predetermined step sizes from the full step, up to 1/32 step.

[Learn More]