TOP Contributors

  1. MIKROE (2784 codes)
  2. Alcides Ramos (404 codes)
  3. Shawon Shahryiar (307 codes)
  4. jm_palomino (133 codes)
  5. Bugz Bensce (97 codes)
  6. S P (73 codes)
  7. dany (71 codes)
  8. MikroBUS.NET Team (35 codes)
  9. NART SCHINACKOW (34 codes)
  10. Armstrong Subero (27 codes)

Most Downloaded

  1. Timer Calculator (141112 times)
  2. FAT32 Library (73906 times)
  3. Network Ethernet Library (58554 times)
  4. USB Device Library (48725 times)
  5. Network WiFi Library (44376 times)
  6. FT800 Library (43977 times)
  7. GSM click (30721 times)
  8. mikroSDK (29478 times)
  9. PID Library (27304 times)
  10. microSD click (27132 times)
Libstock prefers package manager

Package Manager

We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]

< Back
mikroSDK Library

Spectrometer Click

Rating:

0

Author: MIKROE

Last Updated: 2024-10-31

Package Version: 2.1.0.15

mikroSDK Library: 2.0.0.0

Category: Optical

Downloaded: 399 times

Not followed.

License: MIT license  

Spectrometer Click features an 11-channel spectrometer for spectral identification and color matching applications. This Click board™ features the AS7341 from AMS-AG, whose spectral response is defined in the wavelengths from approximately 350nm to 1000nm.

No Abuse Reported

Do you want to subscribe in order to receive notifications regarding "Spectrometer Click" changes.

Do you want to unsubscribe in order to stop receiving notifications regarding "Spectrometer Click" changes.

Do you want to report abuse regarding "Spectrometer Click".

  • mikroSDK Library 1.0.0.0
  • Comments (0)

mikroSDK Library Blog


Spectrometer Click

Spectrometer Click features an 11-channel spectrometer for spectral identification and color matching applications. This Click board™ features the AS7341 from AMS-AG, whose spectral response is defined in the wavelengths from approximately 350nm to 1000nm.

spectrometer_click.png

Click Product page


Click library

  • Author : MikroE Team
  • Date : jul 2020.
  • Type : I2C type

Software Support

We provide a library for the Spectrometer Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly form compilers IDE(recommended way), or downloaded from our LibStock, or found on mikroE github account.

Library Description

This library contains API for Spectrometer Click driver.

Standard key functions :

  • Config Object Initialization function.

    void spectrometer_cfg_setup ( spectrometer_cfg_t *cfg );

  • Initialization function.

    SPECTROMETER_RETVAL spectrometer_init ( spectrometer_t ctx, spectrometer_cfg_t cfg );

  • Default configuration function

    void spectrometer_def_cfg ( spectrometer_t *ctx );

Example key functions :

  • This function is used to read out channels with SMUX configration 1; F1-F4, Clear.

    void spectrometer_raw_rd_val_mode_1 ( spectrometer_t ctx, uint8_t adc_data );

  • This function is used to read out channels with SMUX configration 2; F5-F8, Clear.

    void spectrometer_raw_rd_val_mode_2 ( spectrometer_t ctx, uint8_t adc_data );

  • This function is used to detect flicker for 100 and 120 Hz.

    uint8_t spectrometer_flicker_detection ( spectrometer_t *ctx );

Examples Description

This Click is an 11-channel spectrometer for spectral identification and color matching. The spectral response is defined in the wavelengths from approximately 350nm to 1000nm. 8 optical channels cover the visible spectrum, one channel can be used to measure near infra-red light and one channel is a photo diode without filter (“clear”). The device also integrates a dedicated channel to detect 50Hz or 60Hz ambient light flicker.

The demo application is composed of two sections :

Application Init

Initalizes I2C driver, performs safety check and makes an initial log.


void application_init ( void )
{
    log_cfg_t log_cfg;
    spectrometer_cfg_t cfg;

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_info( &logger, "---- Application Init ----" );

    //  Click initialization.

    spectrometer_cfg_setup( &cfg );
    SPECTROMETER_MAP_MIKROBUS( cfg, MIKROBUS_1 );
    spectrometer_init( &spectrometer, &cfg );
    Delay_ms ( 100 );

    spectrometer_generic_read ( &spectrometer, SPECTROMETER_ID, &id_val, 1 );
    if ( id_val == SPECTROMETER_ID_VALUE )
    {
        log_printf( &logger, "-------------------------\r\n" );
        log_printf( &logger, "   Spectrometer  Click   \r\n" );
        log_printf( &logger, "-------------------------\r\n" );
    }
    else
    {
        log_printf( &logger, "-------------------------\r\n" );
        log_printf( &logger, "     FATAL  ERROR!!!     \r\n" );
        log_printf( &logger, "-------------------------\r\n" );
        for ( ; ; );
    }
    Delay_ms ( 100 );

    spectrometer_def_cfg( &spectrometer );
    Delay_ms ( 100 );
}

Application Task

This example shows the capabilities of the Spectrometer Click by reading out channels with SMUX configrations 1 and 2, detecting flicker for 100 and 120 Hz and displaying data via USART terminal.



void application_task ( void )
{
    spectrometer_raw_rd_val_mode_1( &spectrometer, &adc_buf[ 0 ] );

    ch_0 = adc_buf[ 1 ];
    ch_0 <<= 8;
    ch_0 |= adc_buf[ 0 ];
    log_printf( &logger, " ADC0/F1 : %u\r\n", ch_0 );

    ch_1 = adc_buf[ 3 ];
    ch_1 <<= 8;
    ch_1 |= adc_buf[ 2 ];
    log_printf( &logger, " ADC1/F2 : %u\r\n", ch_1 );

    ch_2 = adc_buf[ 5 ];
    ch_2 <<= 8;
    ch_2 |= adc_buf[ 4 ];
    log_printf( &logger, " ADC2/F3 : %u\r\n", ch_2 );

    ch_3 = adc_buf[ 7 ];
    ch_3 <<= 8;
    ch_3 |= adc_buf[ 6 ];
    log_printf( &logger, " ADC3/F4 : %u\r\n", ch_3 );

    ch_4 = adc_buf[ 9 ];
    ch_4 <<= 8;
    ch_4 |= adc_buf[ 8 ];
    log_printf( &logger, " ADC4/Clear : %u\r\n", ch_4 );

    spectrometer_raw_rd_val_mode_2( &spectrometer, &adc_buf[ 0 ] );

    ch_0 = adc_buf[ 1 ];
    ch_0 <<= 8;
    ch_0 |= adc_buf[ 0 ];
    log_printf( &logger, " ADC0/F5 : %u\r\n", ch_0 );

    ch_1 = adc_buf[ 3 ];
    ch_1 <<= 8;
    ch_1 |= adc_buf[ 2 ];
    log_printf( &logger, " ADC1/F6 : %u\r\n", ch_1 );

    ch_2 = adc_buf[ 5 ];
    ch_2 <<= 8;
    ch_2 |= adc_buf[ 4 ];
    log_printf( &logger, " ADC2/F7 : %u\r\n", ch_2 );

    ch_3 = adc_buf[ 7 ];
    ch_3 <<= 8;
    ch_3 |= adc_buf[ 6 ];
    log_printf( &logger, " ADC3/F8 : %u\r\n", ch_3 );

    ch_4 = adc_buf[ 9 ];
    ch_4 <<= 8;
    ch_4 |= adc_buf[ 8 ];
    log_printf( &logger, " ADC4/Clear : %u\r\n", ch_4 );

    f_val = spectrometer_flicker_detection( &spectrometer );

    log_printf( &logger, " Flicker : " );
    if ( f_val == SPECTROMETER_UNKNOWN_FREQ )
    {
        log_printf( &logger, "unknown\r\n" );
    }
    else if ( f_val == SPECTROMETER_DETECTED_100_HZ )
    {
        log_printf( &logger, "100 Hz detected\r\n" );
    }
    else if ( f_val == SPECTROMETER_DETECTED_120_HZ )
    {
        log_printf( &logger, "120 Hz detected\r\n" );
    }
    else
    {
        log_printf( &logger, "Error in reading\r\n" );
    }

    log_printf( &logger, "-----------------\r\n" );
    Delay_ms ( 1000 );
}  

The full application code, and ready to use projects can be installed directly form compilers IDE(recommneded) or found on LibStock page or mikroE GitHub accaunt.

Other mikroE Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.Spectrometer

Additional notes and informations

Depending on the development board you are using, you may need USB UART Click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all Mikroelektronika compilers, or any other terminal application of your choice, can be used to read the message.


ALSO FROM THIS AUTHOR

mikromedia plus for STM32 and SpeakUp Chess

6

We challenge you to beat an STM32 it in a blitz game. Our chief of software can do it fairly consistently. How well will you fare? You can use the SpeakUp to speak out your moves while you skim a book on chess openings.

[Learn More]

6DOF IMU 25 Click

0

6DOF IMU 25 Click is a compact add-on board for biopotential signal detection and motion tracking applications. This board features the ST1VAFE6AX biosensor from STMicroelectronics, which combines a vertical analog front-end (vAFE) for biopotential sensing with a high-performance 6-axis IMU. The IMU features a 3-axis accelerometer and 3-axis gyroscope with adjustable full-scale ranges, along with advanced functionalities like finite state machine (FSM), adaptive self-configuration (ASC), and a machine learning core (MLC) for on-device processing. The board also includes a 4.5KB FIFO buffer for efficient data handling and supports I2C and SPI communication interfaces for easy integration.

[Learn More]

Button ALARM click

5

Button Alarm Click is a very interesting interactive gadget on a Click board. It is an integrated capacitive touch sensor display in the form of a button.

[Learn More]