TOP Contributors

  1. MIKROE (2784 codes)
  2. Alcides Ramos (384 codes)
  3. Shawon Shahryiar (307 codes)
  4. jm_palomino (118 codes)
  5. Bugz Bensce (97 codes)
  6. S P (73 codes)
  7. dany (71 codes)
  8. MikroBUS.NET Team (35 codes)
  9. NART SCHINACKOW (34 codes)
  10. Armstrong Subero (27 codes)

Most Downloaded

  1. Timer Calculator (139809 times)
  2. FAT32 Library (72200 times)
  3. Network Ethernet Library (57390 times)
  4. USB Device Library (47734 times)
  5. Network WiFi Library (43326 times)
  6. FT800 Library (42698 times)
  7. GSM click (29978 times)
  8. mikroSDK (28431 times)
  9. PID Library (26988 times)
  10. microSD click (26398 times)
Libstock prefers package manager

Package Manager

We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]

< Back
mikroSDK Library

TempHum 16 Click

Rating:

0

Author: MIKROE

Last Updated: 2024-10-31

Package Version: 2.1.0.15

mikroSDK Library: 2.0.0.0

Category: Temperature & humidity

Downloaded: 271 times

Not followed.

License: MIT license  

Temp&Hum 16 Click is a compact add-on board that represents temperature and humidity sensing solutions. This board features the WSEN-HIDS (252.0.0.50001), a MEMS-based capacitive humidity sensor with an integrated ASIC and I2C and SPI serial communication from Würth Elektronik. A silicon-based temperature sensor is also integrated within the same package. ASIC contains the multiplier, operational amplifier, analog-to-digital converter, and other signal conditioning blocks like controller logics and interrupts. It converts the analog signal from humidity and temperature sensing elements into 16-bit digital humidity and temperature values. The 252.0.0.50001 is factory calibrated for both humidity and temperature measurements with no further calibration required. This Click board™ is an ideal solution to be used in various temperature and humidity-related applications.

No Abuse Reported

Do you want to subscribe in order to receive notifications regarding "TempHum 16 Click" changes.

Do you want to unsubscribe in order to stop receiving notifications regarding "TempHum 16 Click" changes.

Do you want to report abuse regarding "TempHum 16 Click".

  • Information
  • Comments (0)

mikroSDK Library Blog


Temp&Hum 16 Click

Temp&Hum 16 Click is a compact add-on board that represents temperature and humidity sensing solutions. This board features the WSEN-HIDS (2525020210001), a MEMS-based capacitive humidity sensor with an integrated ASIC and I2C and SPI serial communication from Würth Elektronik. A silicon-based temperature sensor is also integrated within the same package. ASIC contains the multiplier, operational amplifier, analog-to-digital converter, and other signal conditioning blocks like controller logics and interrupts. It converts the analog signal from humidity and temperature sensing elements into 16-bit digital humidity and temperature values. The 2525020210001 is factory calibrated for both humidity and temperature measurements with no further calibration required. This Click board™ is an ideal solution to be used in various temperature and humidity-related applications.

temphum16_click.png

Click Product page


Click library

  • Author : Nenad Filipovic
  • Date : May 2021.
  • Type : I2C/SPI type

Software Support

We provide a library for the TempHum16 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Library Description

This library contains API for TempHum16 Click driver.

Standard key functions :

  • temphum16_cfg_setup Config Object Initialization function.

    void temphum16_cfg_setup ( temphum16_cfg_t *cfg );
  • temphum16_init Initialization function.

    TEMPHUM16_RETVAL temphum16_init ( temphum16_t *ctx, temphum16_cfg_t *cfg );
  • temphum16_default_cfg Click Default Configuration function.

    void temphum16_default_cfg ( temphum16_t *ctx );

Example key functions :

  • temphum16_check_ready Temp&Hum 16 check ready function.

    uint8_t temphum16_check_ready ( temphum16_t *ctx );
  • temphum16_get_humidity Temp&Hum 16 get humidity function.

    err_t temphum16_get_humidity ( temphum16_t *ctx, float *humidity );
  • temphum16_get_temperature Temp&Hum 16 get temperature function.

    err_t temphum16_get_temperature ( temphum16_t *ctx, float *temperature );

Example Description

This library contains API for the Temp&Hum 16 Click driver. This demo application shows an example of humidity and temperature measurement.

The demo application is composed of two sections :

Application Init

Initialization of SPI or I2C module and log UART. After driver initialization and default settings, the app display retrieves the sensor parameters such as temperature and humidity.


void application_init ( void ) {
    log_cfg_t log_cfg;              /**< Logger config object. */
    temphum16_cfg_t temphum16_cfg;  /**< Click config object. */

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_info( &logger, " Application Init " );

    // Click initialization.

    temphum16_cfg_setup( &temphum16_cfg );
    TEMPHUM16_MAP_MIKROBUS( temphum16_cfg, MIKROBUS_1 );
    err_t init_flag  = temphum16_init( &temphum16, &temphum16_cfg );
    if ( ( init_flag == I2C_MASTER_ERROR ) || ( init_flag == SPI_MASTER_ERROR ) ) {
        log_info( &logger, " Application Init Error. " );
        log_info( &logger, " Please, run program again... " );

        for ( ; ; );
    }

    temphum16_default_cfg ( &temphum16 );
    log_info( &logger, " Application Task " );
    Delay_ms ( 100 );

    temphum16_get_device_id( &temphum16, &device_id );
    log_printf( &logger, "-----------------------\r\n" );
    log_printf( &logger, "  Check communication  \r\n" ); 
    if ( device_id == TEMPHUM16_DEVICE_ID ){
        log_printf( &logger, "      Successful   \r\n" );    
    } else {
        log_printf( &logger, "        Failed     \r\n" );

        for ( ; ; );
    }

    log_printf( &logger, "-----------------------\r\n" );
    log_printf( &logger, "   Start measurements  \r\n" );
    log_printf( &logger, "-----------------------\r\n" );
}

Application Task

This is an example that shows the use of a Temp&Hum 16 Click board™. Logs humidity [ % ] and temperature [ degree Celsius ] data. Results are being sent to the Usart Terminal where you can track their changes.


void application_task ( void ) {
    if ( temphum16_check_ready( &temphum16 ) == TEMPHUM16_DRDY ) {
        temphum16_get_temperature( &temphum16, &temperature );
        log_printf( &logger, " Temperature : %.2f C\r\n", temperature ); 

        temphum16_get_humidity( &temphum16, &humidity );
        log_printf( &logger, " Humidity    : %.2f %%\r\n", humidity ); 
        log_printf( &logger, "-----------------------\r\n" );
        Delay_ms ( 1000 );
    }
}

The full application code, and ready to use projects can be installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Other Mikroe Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.TempHum16

Additional notes and informations

Depending on the development board you are using, you may need USB UART Click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. UART terminal is available in all MikroElektronika compilers.


ALSO FROM THIS AUTHOR

RN4870 Click

0

RN4870 Click carries the RN4870 Bluetooth® 4.2 low energy module from Microchip. The Click is designed to run on a 3.3V power supply. It uses ASCII Command Interface over UART for communication with target microcontroller, with additional functionality provided by the following pins on the mikroBUS™ line: PWM, INT, RST, CS.

[Learn More]

TempHum 5 Click

0

Temp&Hum 5 Click is a temperature and humidity sensing Click board™, packed with features that allow simple integration into any design.

[Learn More]

SWO Trace

10

The ARM SWO trace port uses a single pin to stream out data packets over 32 different ports, using the specified clock rate. The SWO is a part of the ARM® CoreSight Debug module which is incorporated in most of the MCUs based on the Cortex®-M3, M4, and M7 core.

[Learn More]