TOP Contributors

  1. MIKROE (2784 codes)
  2. Alcides Ramos (392 codes)
  3. Shawon Shahryiar (307 codes)
  4. jm_palomino (123 codes)
  5. Bugz Bensce (97 codes)
  6. S P (73 codes)
  7. dany (71 codes)
  8. MikroBUS.NET Team (35 codes)
  9. NART SCHINACKOW (34 codes)
  10. Armstrong Subero (27 codes)

Most Downloaded

  1. Timer Calculator (140535 times)
  2. FAT32 Library (73023 times)
  3. Network Ethernet Library (58026 times)
  4. USB Device Library (48212 times)
  5. Network WiFi Library (43821 times)
  6. FT800 Library (43293 times)
  7. GSM click (30354 times)
  8. mikroSDK (28984 times)
  9. PID Library (27115 times)
  10. microSD click (26717 times)
Libstock prefers package manager

Package Manager

We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]

< Back
mikroSDK Library

Smart Sens Click

Rating:

0

Author: MIKROE

Last Updated: 2024-10-31

Package Version: 2.1.0.10

mikroSDK Library: 2.0.0.0

Category: Environmental

Downloaded: 167 times

Not followed.

License: MIT license  

Smart Sens Click is a compact add-on board that contains an intelligent sensor hub with an integrated IMU sensor. This board utilizes the BHI260 and BMM150, an environmental sensor and magnetometer from Bosch Sensortech. The BHI260 includes a programmable and powerful 32-bit MCU, a 6-axis IMU, and a robust software framework. In addition to its internal functions, it also performs signal data processing from the BMM150 that performs measurements of the magnetic field in three perpendicular axes.

No Abuse Reported

Do you want to subscribe in order to receive notifications regarding "Smart Sens Click" changes.

Do you want to unsubscribe in order to stop receiving notifications regarding "Smart Sens Click" changes.

Do you want to report abuse regarding "Smart Sens Click".

  • Information
  • Comments (0)

mikroSDK Library Blog


Smart Sens Click

Smart Sens Click is a compact add-on board that contains an intelligent sensor hub with an integrated IMU sensor. This board utilizes the BHI260 and BMM150, an environmental sensor and magnetometer from Bosch Sensortech. The BHI260 includes a programmable and powerful 32-bit MCU, a 6-axis IMU, and a robust software framework. In addition to its internal functions, it also performs signal data processing from the BMM150 that performs measurements of the magnetic field in three perpendicular axes.

smartsens_click.png

Click Product page


Click library

  • Author : MikroE Team
  • Date : Oct 2021.
  • Type : I2C/SPI type

Software Support

We provide a library for the Smart Sens Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Library Description

This library contains API for Smart Sens Click driver.

Standard key functions :

  • smartsens_cfg_setup Config Object Initialization function.

    void smartsens_cfg_setup ( smartsens_cfg_t *cfg );
  • smartsens_init Initialization function.

    err_t smartsens_init ( smartsens_t *ctx, smartsens_cfg_t *cfg );
  • smartsens_default_cfg Click Default Configuration function.

    err_t smartsens_default_cfg ( smartsens_t *ctx );

Example key functions :

  • smartsens_cmd_write Send command.

    err_t smartsens_cmd_write ( smartsens_t *ctx, uint16_t cmd, uint8_t *cmd_buf, uint16_t cmd_len );
  • smartsens_get_parameter Get command parameters resposne.

    err_t smartsens_get_parameter ( smartsens_t *ctx, uint16_t parameter, uint8_t *parameter_buf, uint16_t *parameter_len );
  • smartsens_power_on_device Power on device boot/upload firmware to device.

    err_t smartsens_power_on_device( smartsens_t *ctx );

Example Description

This example showcases the ability of the Smart Sens Click board. It has multiple examples that you can easily select with the defines at the top of the main. There are 5 examples: Euler, Quaternion, and Vector (Accelerometer, Gyroscope, Magnetometer).

The demo application is composed of two sections :

Application Init

Initialization of communication modules (SPI/I2C) and additional pins(int_pin, rst). After that going through reset sequence and checking device and product IDs, interrupt mask, and host control is set to 0, so every interrupt enabled. If boot status is OK boot sequence is initiated, depending on the defines from the library header it will use RAM or Flash type of the boot. If RAM is selected firmware image first needs to be uploaded to RAM and then it will be booted. If Flash example is selected it will try to boot firmware first if it fails it will then write firmware image to flash and then try to boot it again. When firmware boot is finished Kernel version and Feature registers will be read to check if the firmware is loaded. Then all the callback function will be registered(meta event callback and whatever type of example parser you set), and driver will update the list of virtual sensors present, and finally will configure virtual sensor that will be used in the selected example.


void application_init ( void )
{
    log_cfg_t log_cfg;  /**< Logger config object. */
    smartsens_cfg_t smartsens_cfg;  /**< Click config object. */

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_info( &logger, " Application Init " );

    // Click initialization.
    smartsens_cfg_setup( &smartsens_cfg );
    SMARTSENS_MAP_MIKROBUS( smartsens_cfg, MIKROBUS_1 );
    err_t init_flag = smartsens_init( &smartsens, &smartsens_cfg );
    if ( ( I2C_MASTER_ERROR == init_flag ) || ( SPI_MASTER_ERROR == init_flag ) )
    {
        log_error( &logger, " Communication init." );
        for ( ; ; );
    }
    /* It can take a few seconds to configure and boot device */
    log_info( &logger, " Configuring device..." );
    if ( SMARTSENS_ERROR == smartsens_default_cfg ( &smartsens ) )
    {
        log_error( &logger, " Default configuration." );
        for ( ; ; );
    }

    log_info( &logger, " Setting callbacks..." );
    /* Set callbacks */
    if ( smartsens_register_fifo_parse_callback( &smartsens, SMARTSENS_SYS_ID_META_EVENT,
                                                  parse_meta_event, &accuracy ) )
    {
        log_error( &logger, " FIFO sys meta event." );
        for ( ; ; );
    }
    if ( smartsens_register_fifo_parse_callback( &smartsens, SMARTSENS_SYS_ID_META_EVENT_WU,
                                                  parse_meta_event, &accuracy ) )
    {
        log_error( &logger, " FIFO sys meta event wu." );
        for ( ; ; );
    }
    uint8_t sensor_id;
    smartsens_fifo_parse_callback_t callback;
    void *callback_ref;
#if EULER
    sensor_id = SMARTSENS_SENSOR_ID_ORI;
    callback = parse_euler;
    callback_ref = &accuracy;
#elif QUATERNION
    sensor_id = SMARTSENS_SENSOR_ID_RV;
    callback = parse_quaternion;
    callback_ref = NULL;
#elif VECTOR
    #if ACCELEROMETER
        parse_table.sensor[ SMARTSENS_SENSOR_ID_ACC ].scaling_factor = 1.0f / 4096.0f;
        sensor_id = SMARTSENS_SENSOR_ID_ACC;
    #elif GYROSCOPE
        parse_table.sensor[ SMARTSENS_SENSOR_ID_GYRO ].scaling_factor = 1.0f;
        sensor_id = SMARTSENS_SENSOR_ID_GYRO;
    #elif MAGNETOMETER
        parse_table.sensor[ SMARTSENS_SENSOR_ID_MAG ].scaling_factor = 1.0f;
        sensor_id = SMARTSENS_SENSOR_ID_MAG;
    #else
        #error NO_VECTOR_EXAMPLE_DEFINED
    #endif
    callback = parse_vector_s16;
    callback_ref = &parse_table;
#else
    #error NO_EXAMPLE_DEFINED
#endif
    if ( smartsens_register_fifo_parse_callback( &smartsens, sensor_id, callback, callback_ref ) )
    {
        log_error( &logger, " FIFO sensor id." );
        for ( ; ; );
    }
    /* Go through fifo process */
    if ( smartsens_get_and_process_fifo( &smartsens, work_buffer, WORK_BUFFER_SIZE ) )
    {
        log_error( &logger, " FIFO get and process." );
        for ( ; ; );
    }
    /* Update virtual sensor list in context object */
    if ( smartsens_update_virtual_sensor_list( &smartsens ) )
    {
        log_error( &logger, " Update virtual sensor list." );
        for ( ; ; );
    }
    /* Set virtual sensor configuration */
    float sample_rate = 10.0; /* Read out data at 10Hz */
    uint32_t report_latency_ms = 0; /* Report immediately */
    if ( smartsens_set_virt_sensor_cfg( &smartsens, sensor_id, sample_rate, report_latency_ms ) )
    {
        log_error( &logger, " Set virtual sensor configuration." );
        for ( ; ; );
    }

    log_info( &logger, " Application Task " );
}

Application Task

Wait for an interrupt to occur, then read wake-up, non-weak-up, and status FIFO. Parse received data and run the callback parsers to show data on the USB UART.

void application_task ( void )
{
    /* Check interrupt and get and process fifo buffer */
    if ( smartsens_get_interrupt( &smartsens ) )
    {
        /* Data from the FIFO is read and the relevant callbacks if registered are called */
        if ( smartsens_get_and_process_fifo( &smartsens, work_buffer, WORK_BUFFER_SIZE ) )
        {
            log_error( &logger, " Get and process fifo." );
            for ( ; ; );
        }
    }
}

Note

Select one of the examples with macros at the top of the main file. Euler example is selected by default. You can choose one of 3 type of parsers: Euler, Quaternion, Vector. If Vector example is selected you choose one of the 3 sensors to show X, Y, and Z values: Accelerometer, Gyroscope, or Magnetometer.

The full application code, and ready to use projects can be installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Other Mikroe Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.SmartSens

Additional notes and informations

Depending on the development board you are using, you may need USB UART Click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. UART terminal is available in all MikroElektronika compilers.


ALSO FROM THIS AUTHOR

Fan 6 Click

0

The Fan 6 Click is a Click board™ which features EMC2103, an SMBus compliant fan controller with up to up to 3 external and 1 internal temperature channels.

[Learn More]

Remote Weather Station with ClickCloud platform

0

The most popular topic with which we all start the day is the weather. You can measure temperature, humidity, ambient lighting and UV and IR indexes in real time, easily, with our Weather Station Kit. Access this data remotely by adding our G2C click–a reliable connection to the Click Cloud platform, a cloud-based rapid prototyping environment.

[Learn More]

Buck 23 Click

0

Buck 23 Click is a compact add-on board with a DC-DC power converter that steps down the voltage from its input to its output. This board features the MAX20010C, a fully-integrated, high-efficiency, synchronous, step-down converter from Analog Devices. The MAX20010C achieves 6A continuous output current over a wide input supply range from 3V to 5.5V. It offers ±2% output voltage accuracy and can operate efficiently over interface-configurable output voltage load range from 0.5V to 1.58V. The MAX20010C also offers programmable soft-start, overcurrent, and overtemperature protections.

[Learn More]