TOP Contributors

  1. MIKROE (2779 codes)
  2. Alcides Ramos (376 codes)
  3. Shawon Shahryiar (307 codes)
  4. jm_palomino (118 codes)
  5. Bugz Bensce (97 codes)
  6. S P (73 codes)
  7. dany (71 codes)
  8. MikroBUS.NET Team (35 codes)
  9. NART SCHINACKOW (34 codes)
  10. Armstrong Subero (27 codes)

Most Downloaded

  1. Timer Calculator (139566 times)
  2. FAT32 Library (72041 times)
  3. Network Ethernet Library (57255 times)
  4. USB Device Library (47615 times)
  5. Network WiFi Library (43219 times)
  6. FT800 Library (42566 times)
  7. GSM click (29930 times)
  8. mikroSDK (28292 times)
  9. PID Library (26933 times)
  10. microSD click (26309 times)
Libstock prefers package manager

Package Manager

We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]

< Back
mikroSDK Library

ADC 8 Click

Rating:

0

Author: MIKROE

Last Updated: 2024-10-31

Package Version: 2.1.0.17

mikroSDK Library: 2.0.0.0

Category: ADC

Downloaded: 336 times

Not followed.

License: MIT license  

ADC 8 Click is a high precision, low-power, 16-bit analog-to-digital converter (ADC), based around the ADS1115 IC.

No Abuse Reported

Do you want to subscribe in order to receive notifications regarding "ADC 8 Click" changes.

Do you want to unsubscribe in order to stop receiving notifications regarding "ADC 8 Click" changes.

Do you want to report abuse regarding "ADC 8 Click".

  • mikroSDK Library 1.0.0.0
  • Comments (0)

mikroSDK Library Blog


ADC 8 Click

ADC 8 Click is a high precision, low-power, 16-bit analog-to-digital converter (ADC), based around the ADS1115 IC.

adc8_click.png

Click Product page


Click library

  • Author : Katarina Perendic
  • Date : okt 2019.
  • Type : I2C type

Software Support

We provide a library for the Adc8 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly form compilers IDE(recommended way), or downloaded from our LibStock, or found on mikroE github account.

Library Description

This library contains API for Adc8 Click driver.

Standard key functions :

  • Config Object Initialization function.

    void adc8_cfg_setup ( adc8_cfg_t *cfg );

  • Initialization function.

    ADC8_RETVAL adc8_init ( adc8_t ctx, adc8_cfg_t cfg );

  • Click Default Configuration function.

    void adc8_default_cfg ( adc8_t *ctx );

Example key functions :

  • Get [Package] Diff channel voltage

    void adc8_get_diff_channel( adc8_t ctx, adc8_diff_volt_t volt );

  • Get [Package] Single channel voltage

    void adc8_get_single_channel( adc8_t ctx, adc8_single_volt_t volt );

  • Get interrupt pin state

    uint8_t adc8_get_interrupt_state( adc8_t *ctx );

Examples Description

The demo app shows voltage measurement across all singles and different channels.

The demo application is composed of two sections :

Application Init

Configuring Clicks and log objects. Settings the Click in the default configuration.

void application_init ( void )
{
    log_cfg_t log_cfg;
    adc8_cfg_t cfg;

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_info( &logger, "---- Application Init ----" );

    //  Click initialization.

    adc8_cfg_setup( &cfg );
    ADC8_MAP_MIKROBUS( cfg, MIKROBUS_1 );
    adc8_init( &adc8, &cfg );

    adc8_default_cfg( &adc8 );
    log_info( &logger, "---- ADC start ----" );
}

Application Task

Reads voltage from each channel one by one and the voltage difference between specified channels.

void application_task ( void )
{
    adc8_single_volt_t single_volt;
    adc8_diff_volt_t diff_volt;

    log_printf( &logger, "\r\n-----------------------------------" );

    // Single channel
    adc8_get_single_channel( &adc8, &single_volt );

    log_printf( &logger, "\r\n>>> SINGLE CHANNEL <<<<\r\n" );
    log_printf( &logger, "- CH 0: %.2f\r\n", single_volt.ch_0 );
    log_printf( &logger, "- CH 1: %.2f\r\n", single_volt.ch_1 );
    log_printf( &logger, "- CH 2: %.2f\r\n", single_volt.ch_2 );
    log_printf( &logger, "- CH 3: %.2f\r\n", single_volt.ch_3 );

    // Diff channel

    adc8_get_diff_channel( &adc8, &diff_volt );

    log_printf( &logger, "\r\n>>> DIFF CHANNEL <<<<\r\n" );
    log_printf( &logger, "- CH(0-1): %.2f\r\n", diff_volt.ch_0_1 );
    log_printf( &logger, "- CH(0-3): %.2f\r\n", diff_volt.ch_0_3 );
    log_printf( &logger, "- CH(1-3): %.2f\r\n", diff_volt.ch_1_3 );
    log_printf( &logger, "- CH(2-3): %.2f\r\n", diff_volt.ch_2_3 );

    Delay_ms ( 1000 );
}

Note

On the input channel AIN0, AIN1, AIN2 and AIN3 sets maximum voltage GND - 0.3V < VIN > VDD + 0.3V

The full application code, and ready to use projects can be installed directly form compilers IDE(recommneded) or found on LibStock page or mikroE GitHub accaunt.

Other mikroE Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.Adc8

Additional notes and informations

Depending on the development board you are using, you may need USB UART Click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all Mikroelektronika compilers, or any other terminal application of your choice, can be used to read the message.


ALSO FROM THIS AUTHOR

Ozone 3 Click

0

Ozone 3 Click is a compact add-on board suitable for ozone concentration detection and monitoring. This board features the 110-407, a high-performance ultra-thin electrochemical gas sensor from SPEC Sensors supported by the LMP91000, a high-precision integrated analog front-end IC (AFE) ideal for this sensing application. It provides the reference voltage required by the sensor and offers a choice between the analog output from the AFE IC buffered with the low noise Op-Amp and digital output from the 12-bit SAR A/D converter. This Click board™ represents an ideal choice for health, environmental, industrial, and residential monitoring.

[Learn More]

Pollution Click

0

Pollution Click carries the VOC gas sensor and has high sensitivity to organic gases such as methanal (also known as formaldehyde), benzene, alcohol, toluene, etc.

[Learn More]

Power MUX Click

0

Power MUX Click features power multiplexer that enables transition between two power supplies (such as a battery and a wall adapter), each operating at 2.8V to 5.5V and delivering up to 2A current depending on the package. This IC provides inrush current control and thermal protection to Power MUX Click, manual and auto-switching operating modes, cross-conduction blocking, and reverse-conduction blocking.

[Learn More]