TOP Contributors

  1. MIKROE (2784 codes)
  2. Alcides Ramos (405 codes)
  3. Shawon Shahryiar (307 codes)
  4. jm_palomino (133 codes)
  5. Bugz Bensce (97 codes)
  6. S P (73 codes)
  7. dany (71 codes)
  8. MikroBUS.NET Team (35 codes)
  9. NART SCHINACKOW (34 codes)
  10. Armstrong Subero (27 codes)

Most Downloaded

  1. Timer Calculator (142015 times)
  2. FAT32 Library (75246 times)
  3. Network Ethernet Library (59469 times)
  4. USB Device Library (49488 times)
  5. Network WiFi Library (45265 times)
  6. FT800 Library (44873 times)
  7. GSM click (31414 times)
  8. mikroSDK (30400 times)
  9. microSD click (27776 times)
  10. PID Library (27613 times)
Libstock prefers package manager

Package Manager

We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]

< Back
mikroSDK Library

VCP Monitor click

Rating:

5

Author: MIKROE

Last Updated: 2020-03-16

Package Version: 1.0.0.0

mikroSDK Library: 1.0.0.0

Category: Current sensor

Downloaded: 3552 times

Not followed.

License: MIT license  

The VCP Monitor Click is add-on board power monitor system. This Click board is based on INA260AIPWR - precision digital current and power monitor with low-drift, integrated precision shunt resistor, from Texas Instruments.

No Abuse Reported

Do you want to subscribe in order to receive notifications regarding "VCP Monitor click" changes.

Do you want to unsubscribe in order to stop receiving notifications regarding "VCP Monitor click" changes.

Do you want to report abuse regarding "VCP Monitor click".

  • mikroSDK Library 2.0.0.0
  • Comments (0)
DOWNLOAD LINK RELATED COMPILER CONTAINS
mikroBasic PRO for ARM
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroBasic PRO for AVR
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroBasic PRO for dsPIC30/33 & PIC24
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroBasic PRO for FT90x
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroBasic PRO for PIC
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroBasic PRO for PIC32
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroC PRO for ARM
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroC PRO for AVR
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroC PRO for dsPIC30/33 & PIC24
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroC PRO for FT90x
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroC PRO for PIC
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroC PRO for PIC32
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroPascal PRO for ARM
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroPascal PRO for AVR
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroPascal PRO for dsPIC30/33 & PIC24
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroPascal PRO for FT90x
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroPascal PRO for PIC
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc
mikroPascal PRO for PIC32
  • lib
  • src
  • exa
  • hlp
  • hex
  • sch
  • pcb
  • doc

mikroSDK Library Blog

VCP Monitor Click

VCP Monitor Click

Native view of the VCP Monitor Click board.

View full image
VCP Monitor Click

VCP Monitor Click

Front and back view of the VCP Monitor Click board.

View full image

Library Description

The library contains basic communication with the module and allows the user to read and write data to the module. The user can read the current data of current, voltage and power measured by the sensor.

Key functions:

  • float vcpmonitor_get_voltage ( void ) - Reads voltage data in mV
  • float vcpmonitor_get_current ( void ) - Reads current data in mA
  • float vcpmonitor_get_power ( void ) - Reads power data in mW

Examples description

The application is composed of three sections :

  • System Initialization - Initializes I2C module and INT pin on INPUT
  • Application Initialization - Initializes driver init, check device ID and manufacture ID, start default configuration.
  • Application Task - Reads Current, Voltage and Power data. This data logs to USB UART every 1500ms.
void application_task ( )
{
    float current_data;
    float voltage_data;
    float power_data;
    
    current_data = vcpmonitor_get_current(  );
    IntToStr( current_data, demo_text );
    mikrobus_logWrite( ">> Current data: ", _LOG_TEXT );
    mikrobus_logWrite( demo_text, _LOG_TEXT );
    mikrobus_logWrite( " mA", _LOG_LINE );
     
    voltage_data = vcpmonitor_get_voltage(  );
    IntToStr( voltage_data, demo_text );
    mikrobus_logWrite( ">> Voltage data: ", _LOG_TEXT );
    mikrobus_logWrite( demo_text, _LOG_TEXT );
    mikrobus_logWrite( " mV", _LOG_LINE );
    
    power_data = vcpmonitor_get_power(  );
    IntToStr( power_data, demo_text );
    mikrobus_logWrite( ">> Power data: ", _LOG_TEXT );
    mikrobus_logWrite( demo_text, _LOG_TEXT );
    mikrobus_logWrite( " mW", _LOG_LINE );
    
    mikrobus_logWrite( " ------------------------------- ", _LOG_LINE );
    Delay_ms( 1500 );
}

Other mikroE Libraries used in the example:

  • I2C Library
  • Conversions library

Additional notes and informations

Depending on the development board you are using, you may need USB UART clickUSB UART 2 click or RS232 click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all MikroElektronika compilers, or any other terminal application of your choice, can be used to read the message.

ALSO FROM THIS AUTHOR

Buck 8 Click

5

Buck 8 click is a high efficiency, wide voltage range, and high current synchronous step down (buck) DC-DC converter, featuring two enhanced modes used to drive lighter loads with increased efficiency. The output voltage can be adjusted by the multi-turn trimmer potentiometer.

[Learn More]

SMS home alarm system

16

Build your own home-made SMS alarm system, with minimum expenses using StartUSB for PIC, Smart GM862 with Telit GM862 module and antenna, Motion Sensor and a wire jumpers.

[Learn More]

Smart DOF 4 Click

0

Smart DOF 4 Click is a compact add-on board for high-precision motion tracking and contextual sensing. This board features the BNO085, a 9-axis IMU System in Package (SiP) from CEVA, combining an accelerometer, gyroscope, and geomagnetic sensor with a 32-bit microcontroller running CEVA's SH-2 firmware. The board provides real-time, calibrated 3D orientation, linear acceleration, and angular velocity while dynamically compensating for temperature changes and sensor aging. It supports I2C and SPI interfaces, features advanced MotionEngineā„¢ technology for gesture detection and activity monitoring, and includes 'Always-On' capabilities like step counting and stability detection.

[Learn More]