TOP Contributors

  1. MIKROE (2762 codes)
  2. Alcides Ramos (374 codes)
  3. Shawon Shahryiar (307 codes)
  4. jm_palomino (118 codes)
  5. Bugz Bensce (91 codes)
  6. S P (73 codes)
  7. dany (71 codes)
  8. MikroBUS.NET Team (35 codes)
  9. NART SCHINACKOW (34 codes)
  10. Armstrong Subero (27 codes)

Most Downloaded

  1. Timer Calculator (139270 times)
  2. FAT32 Library (71755 times)
  3. Network Ethernet Library (57128 times)
  4. USB Device Library (47432 times)
  5. Network WiFi Library (43093 times)
  6. FT800 Library (42408 times)
  7. GSM click (29835 times)
  8. mikroSDK (28103 times)
  9. PID Library (26886 times)
  10. microSD click (26198 times)
Libstock prefers package manager

Package Manager

We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]

< Back
mikroSDK Library

Air quality 5 Click

Rating:

0

Author: MIKROE

Last Updated: 2024-10-31

Package Version: 2.1.0.17

mikroSDK Library: 2.0.0.0

Category: Gas

Downloaded: 304 times

Not followed.

License: MIT license  

Air quality 5 Click is a triple MOS sensor on a single Click board™, which can detect gas pollution for a number of different gases. The onboard sensor is specially designed to detect the pollution from automobile exhausts, as well as the gas pollution from the industrial or agricultural industry.

No Abuse Reported

Do you want to subscribe in order to receive notifications regarding "Air quality 5 Click" changes.

Do you want to unsubscribe in order to stop receiving notifications regarding "Air quality 5 Click" changes.

Do you want to report abuse regarding "Air quality 5 Click".

  • mikroSDK Library 1.0.0.0
  • Comments (0)

mikroSDK Library Blog

Air quality 5 Click

Air quality 5 Click is a triple MOS sensor on a single Click board™, which can detect gas pollution for a number of different gases. The onboard sensor is specially designed to detect the pollution from automobile exhausts, as well as the gas pollution from the industrial or agricultural industry.

airquality5_click.png

Click Product page


Click library

  • Author : MikroE Team
  • Date : dec 2019.
  • Type : I2C type

Software Support

We provide a library for the Airquality5 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly form compilers IDE(recommended way), or downloaded from our LibStock, or found on mikroE github account.

Library Description

This library contains API for Airquality5 Click driver.

Standard key functions :

  • Config Object Initialization function.

    void airquality5_cfg_setup ( airquality5_cfg_t *cfg );

  • Initialization function.

    AIRQUALITY5_RETVAL airquality5_init ( airquality5_t ctx, airquality5_cfg_t cfg );

  • Click Default Configuration function.

    void airquality5_default_cfg ( airquality5_t *ctx );

Example key functions :

  • Functions for write data in register.

    void airq5_write_data ( airquality5_t *ctx, uint8_t reg, uint16_t data_b );

  • Functions for read data from register.

    uint16_t airq5_read_data ( airquality5_t *ctx, uint8_t reg );

  • Functions for configuration.

    void airq5_set_configuration ( airquality5_t *ctx, uint16_t config );

Examples Description

This application can detect gas pollution for a number of different gases.

The demo application is composed of two sections :

Application Init

Initializes device and configuration chip.


void application_init ( void )
{
    log_cfg_t log_cfg;
    airquality5_cfg_t cfg;
    airquality5.data_config = 0x8583;

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_info( &logger, "---- Application Init ----" );

    airquality5_cfg_setup( &cfg );
    AIRQUALITY5_MAP_MIKROBUS( cfg, MIKROBUS_1 );
    airquality5_init( &airquality5, &cfg );
}

Application Task

Reads the values of CO, NH3 and NO2 sensor and logs data on USBUART every 500ms.


void application_task ( void )
{
    uint16_t NO2_sensor_data;
    uint16_t NH3_sensor_data;
    uint16_t CO_sensor_data;

    CO_sensor_data = airq5_read_sensor_data( &airquality5, AIRQ5_DATA_CHANNEL_CO );

    NO2_sensor_data = airq5_read_sensor_data( &airquality5, AIRQ5_DATA_CHANNEL_NO2 );
    log_printf( &logger, " NO2 data: %d\r\n", NO2_sensor_data );

    NH3_sensor_data = airq5_read_sensor_data( &airquality5, AIRQ5_DATA_CHANNEL_NH3 );
    log_printf( &logger, " NH3 data: %d\r\n", NH3_sensor_data );

    CO_sensor_data = airq5_read_sensor_data( &airquality5, AIRQ5_DATA_CHANNEL_CO );
    log_printf( &logger," CO data: %d\r\n", CO_sensor_data );

    log_printf( &logger, " -------- ");
    Delay_ms ( 200 );
}  

The full application code, and ready to use projects can be installed directly form compilers IDE(recommneded) or found on LibStock page or mikroE GitHub accaunt.

Other mikroE Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.Airquality5

Additional notes and informations

Depending on the development board you are using, you may need USB UART Click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all Mikroelektronika compilers, or any other terminal application of your choice, can be used to read the message.


ALSO FROM THIS AUTHOR

MIC33153 Click

0

MIC33153 Click is a DC-DC adjustable step-down (buck) converter that is designed to deliver a substantial amount of current to very demanding loads, with the voltage output up to 3.5V.

[Learn More]

DMX click

5

DMX Click is a device used to establish communication between the MCU and equipment that uses the DMX512-A communication protocol.

[Learn More]

Current Limit 6 Click

0

Current Limit 6 Click is a compact add-on board representing a current-limiting solution. This board features the MAX17608, adjustable overvoltage, and overcurrent protection device from Maxim Integrated, now part of Analog Devices. This Click board™ is ideal for protecting systems with the flexible input overvoltage protection range from 4.5V to 60V, and the adjustable input undervoltage protection range is 4.5V to 59V. Also, the maximum current limit is 1A and can be programmed through a digital potentiometer MAX5401. When the device current reaches the programmed threshold, the device prevents further current increases by modulating the FET resistance.

[Learn More]