TOP Contributors

  1. MIKROE (2784 codes)
  2. Alcides Ramos (405 codes)
  3. Shawon Shahryiar (307 codes)
  4. jm_palomino (133 codes)
  5. Bugz Bensce (97 codes)
  6. S P (73 codes)
  7. dany (71 codes)
  8. MikroBUS.NET Team (35 codes)
  9. NART SCHINACKOW (34 codes)
  10. Armstrong Subero (27 codes)

Most Downloaded

  1. Timer Calculator (141304 times)
  2. FAT32 Library (74107 times)
  3. Network Ethernet Library (58718 times)
  4. USB Device Library (48831 times)
  5. Network WiFi Library (44526 times)
  6. FT800 Library (44078 times)
  7. GSM click (30834 times)
  8. mikroSDK (29673 times)
  9. PID Library (27357 times)
  10. microSD click (27251 times)
Libstock prefers package manager

Package Manager

We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]

< Back
mikroSDK Library

VCP Monitor 3 Click

Rating:

0

Author: MIKROE

Last Updated: 2024-10-31

Package Version: 2.1.0.13

mikroSDK Library: 2.0.0.0

Category: Measurements

Downloaded: 225 times

Not followed.

License: MIT license  

VCP Monitor 3 Click is a high precision Voltage, Current and Power measurement Click board™ with an input capable of taking up to 15V. It features the LTC2947, from Analog Devices, a high precision power and energy monitor with an internal sense resistor supporting up to ±30A.

No Abuse Reported

Do you want to subscribe in order to receive notifications regarding "VCP Monitor 3 Click" changes.

Do you want to unsubscribe in order to stop receiving notifications regarding "VCP Monitor 3 Click" changes.

Do you want to report abuse regarding "VCP Monitor 3 Click".

  • mikroSDK Library 1.0.0.0
  • Comments (0)

mikroSDK Library Blog


VCP Monitor 3 Click

VCP Monitor 3 Click is a high precision Voltage, Current and Power measurement Click board™ with an input capable of taking up to 15V. It features the LTC2947, from Analog Devices, a high precision power and energy monitor with an internal sense resistor supporting up to ±30A.

vcpmonitor3_click.png

Click Product page


Click library

  • Author : Mikroe Team
  • Date : Oct 2021.
  • Type : I2C/SPI type

Software Support

We provide a library for the VCPMonitor3 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Library Description

This library contains API for VCPMonitor3 Click driver.

Standard key functions :

  • vcpmonitor3_cfg_setup Config Object Initialization function.

    void vcpmonitor3_cfg_setup ( vcpmonitor3_cfg_t *cfg );
  • vcpmonitor3_init Initialization function.

    err_t vcpmonitor3_init ( vcpmonitor3_t *ctx, vcpmonitor3_cfg_t *cfg );
  • vcpmonitor3_default_cfg Click Default Configuration function.

    err_t vcpmonitor3_default_cfg ( vcpmonitor3_t *ctx );

Example key functions :

  • vcpmonitor3_rd_page_0 Read Data From Page 0 function.

    void vcpmonitor3_rd_page_0 ( vcpmonitor3_t *ctx, uint8_t reg, uint8_t *rd_data, uint8_t n_bytes );
  • vcpmonitor3_set_op_mode Set Operation Mode function.

    void vcpmonitor3_set_op_mode ( vcpmonitor3_t *ctx, uint8_t op_mode );
  • vcpmonitor3_read_p Read Power in Watts function.

    float vcpmonitor3_read_p ( vcpmonitor3_t *ctx );

Example Description

VCP Monitor 3 Click show it's full usage by reading current, voltage, power, die temperature and voltage at DVCC using SPI or I2C communication protocol.

The demo application is composed of two sections :

Application Init

Initalizes SPI or I2C driver and sets up the device.


void application_init ( void )
{
    log_cfg_t log_cfg;  /**< Logger config object. */
    vcpmonitor3_cfg_t vcpmonitor3_cfg;  /**< Click config object. */

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_info( &logger, " Application Init " );

    // Click initialization.
    vcpmonitor3_cfg_setup( &vcpmonitor3_cfg );
    VCPMONITOR3_MAP_MIKROBUS( vcpmonitor3_cfg, MIKROBUS_1 );
    err_t init_flag  = vcpmonitor3_init( &vcpmonitor3, &vcpmonitor3_cfg );
    if ( ( I2C_MASTER_ERROR == init_flag ) || ( SPI_MASTER_ERROR == init_flag ) )
    {
        log_error( &logger, " Communication init." );
        for ( ; ; );
    }

    if ( VCPMONITOR3_ERROR == vcpmonitor3_default_cfg ( &vcpmonitor3 ) )
    {
        log_error( &logger, " Default configuration." );
        for ( ; ; );
    }

    log_info( &logger, " Application Task " );
}

Application Task

This example shows capabilities of VCP Monitor 3 Click board by reading current, voltage, power, die temperature and voltage at DVCC and displaying the results via USART terminal.


void application_task ( void )
{
    volt_data = vcpmonitor3_read_v( &vcpmonitor3 );
    log_printf( &logger, " Voltage :         %.2f V \r\n", volt_data );

    cur_data = vcpmonitor3_read_i( &vcpmonitor3 );
    log_printf( &logger, " Current :         %.2f A \r\n", cur_data );

    pow_data = vcpmonitor3_read_p( &vcpmonitor3 );
    log_printf( &logger, " Power :           %.2f W \r\n", pow_data );

    die_temp = vcpmonitor3_read_temp( &vcpmonitor3 );
    log_printf( &logger, " Die Temperature : %.2f C \r\n", die_temp );

    volt_vcc = vcpmonitor3_read_vcc( &vcpmonitor3 );
    log_printf( &logger, " Voltage at DVCC : %.2f V \r\n", volt_vcc );

    log_printf( &logger, " ------------------------------- \r\n" );
    Delay_ms ( 1000 );
}

The full application code, and ready to use projects can be installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Other Mikroe Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.VCPMonitor3

Additional notes and informations

Depending on the development board you are using, you may need USB UART Click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. UART terminal is available in all MikroElektronika compilers.


ALSO FROM THIS AUTHOR

Ambient 19 Click

0

Ambient 19 Click is a compact add-on board used to measure the amount of the present ambient light. This board features the APM-16D24-310-DF8/TR8, a digital output ambient light and proximity sensor with an I2C interface and interrupt from Everlight Electronics. It has a flexible and wide operating range for the ambient light sensor with a maximum resolution of 0.0023Lux/count and full detectable illumination of 57880Lux. The proximity function has an adjustable number of IR pulses from 1 to 256, and a flexible IR LED driving current to meet different application requirements. It is also equipped with an integrated filter to reduce unwanted IR signals and noise from the environment.

[Learn More]

Temp-Hum 2 click

5

Temp-Hum 2 click is a smart temperature and humidity sensor click board, packed with features, that allow easy and simple integration into any design that requires accurate and reliable humidity and temperature measurements.

[Learn More]

TempHum 24 Click

0

Temp&Hum 24 Click is a compact add-on board that measures the surrounding environment's humidity and temperature. This board features the HDC3021, an integrated capacitive-based relative humidity and temperature sensor with a removable tape cover from Texas Instruments. The HDC3021 is characterized by its high accuracy (±0.5%RH and ±0.1°C over a wide operating temperature range) and high resolution, providing 16-bit data to the host controller with a configurable I2C interface. Offset Error Correction reduces RH sensor offset due to aging, exposure to extreme operating conditions, and contaminants to return the device to within accuracy specifications.

[Learn More]