Libstock prefers package manager

Package Manager

We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]

Project Request

Return
Petar Timotijević
tpetar

posted on 2012/08/13 06:59:57 PM CEST

Graphics & LCD

Water Boiler Control Touch GLCD 128x64 and 1-Wire

Hi to all,

I need to control water boiler over touch GLCD 128x64 and 1-Wire DS18B20 sensors, using PIC18F45K22 (EasyPIC v7 dev board).

Scenario:
- Boiler have 80L (vertical)
- Temp measurement is done over 5 DS18B20, for sensing level and amount of hot water on 5 boiler points (1 bottom--2-- 3 middle--4--5 top)
- On GLCD user set temp on one of 5 sensors, uC monitor value of that particular sensor and like thermostat over DS2406 switch of or on relay to turn off or on heater element inside boiler.
- On GLCD user can monitor curve of water temp raising in boiler, or with graphical boiler on GLCD with raising filling white filled area representing raising of hot water level.
- Manually control Off & On heater element should exist.

This device can be used from main room, to control water boiler in remote bathroom over 1-wire.